Related Experiment Video
Updated: Jan 6, 2026

Calculating Heart Rate Variability from ECG Data from Youth with Cerebral Palsy During Active Video Game Sessions
Published on: June 5, 2019
Pulse Rate Variability in Emergency Physicians During Shifts: Pilot Cross-Sectional Study
Gregory Andrew Peters1,2, Matthew L Wong1,2, Joshua W Joseph1,2
1Department of Emergency Medicine, Beth Israel Deaconess Medical Center, Boston, MA, United States.
Background:
The high prevalence of physician burnout, particularly in emergency medicine, has garnered national attention in recent years. Objective means of measuring stress while at work can facilitate research into stress reduction interventions, and wearable photoplethysmography (PPG) technology has been proposed as a potential solution. However, the use of low-burden wearable biosensors to study training and clinical practice among emergency physicians (EP) remains untested.
Objective:
This pilot study aimed to (1) determine the feasibility of recording on-shift photoplethysmographic data from EP, (2) assess the quality of these data, and (3) calculate standard pulse rate variability (PRV) metrics from the acquired dataset and examine patterns in these variables over the course of an academic year.
Methods:
A total of 21 EP wore PPG biosensors on their wrists during clinical work in the emergency department during a 9-hour shift. Recordings were collected during the first quarter of the academic year, then again during the fourth quarter of the same year for comparison. The overall rate of usable data collection per time was computed. Standard pulse rate (PR) and PRV metrics from these two time points were calculated and entered into Student t tests.
Results:
More than 400 hours of data were entered into these analyses. Interpretable data were captured during 8.54% of the total recording time overall. In the fourth quarter of the academic year compared with the first quarter, there was no significant difference in median PR (75.8 vs 76.8; P=.57), mean R-R interval (0.81 vs 0.80; P=.32), SD of R-R interval (0.11 vs 0.11; P=.93), root mean square of successive difference of R-R interval (0.81 vs 0.80; P=.96), low-frequency power (3.5×103 vs 3.4×103; P=.79), high-frequency power (8.5×103 vs 8.3×103; P=.91), or low-frequency to high-frequency ratio (0.42 vs 0.41; P=.43), respectively. Power estimates for each of these tests exceeded .90. A secondary analysis of the resident-only subgroup similarly showed no significant differences over time, despite power estimates greater than .80.
Conclusions:
Although the use of PPG biosensors to record real-time physiological data from EP while providing clinical care seems operationally feasible, this study fails to support the notion that such an approach can efficiently provide reliable estimates of metrics of interest. No significant differences in PR or PRV metrics were found at the end of the year compared with the beginning. Although these methods may offer useful applications to other domains, it may currently have limited utility in the contexts of physician training and wellness.
More Related Videos
07:49Author Spotlight: Investigating HR-Dependent Cardiac Function in Mouse Models Through a Novel Atrial-Pacing Approach
Published on: July 21, 2023
08:22Author Spotlight: Advancing the Study of Brain-Heart Interplay with a Comprehensive EEGLAB Plugin for Multimodal Signal Analysis
Published on: April 26, 2024
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Dysrhythmias III: Characteristics of Dysrhythmias
Special considerations while measuring pulse
Pulse
The pulse serves as a clinical...
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...