Effect of grid geometry on the transmission properties of 2D grids for flat detectors in CBCT
Cem Altunbas1,2, Timur Alexeev1, Moyed Miften1
1Department of Radiation Oncology, University of Colorado School of Medicine, 1665 Aurora Court, Suite 1032, Mail stop F-706 Aurora, CO 80045, United States of America.
Abstract:
To suppress scatter in cone beam computed tomography (CBCT), two-dimensional antiscatter grids (2D grid) have been recently proposed. In this work, we developed several grid prototypes with higher grid ratios and smaller grid pitches than previous designs, and quantified their primary and scatter transmission properties in the context of CBCT for radiation therapy. Three focused 2D grid prototypes were developed with grid ratios at 12 and 16, and grid pitches at 2 and 3 mm. Their scatter transmission properties were measured between 80-140 kVp, and benchmarked against a high performance radiographic grid (1D grid) using a Varian TrueBeam CBCT system. The effect of source-grid misalignment on the primary transmission and the improvement in contrast-to-noise ratio (CNR) were also evaluated. Changing the grid pitch from two to three mm increased the average primary transmission from 84% to 89%. Maximum scatter-to-primary ratio (SPR) with grid ratio of 12 was 0.3, and increasing the grid ratio to 16 reduced SPR by 30%. A 10 mm misalignment in 2D grid position led to a 6%-8% reduction in average primary transmission, and reduction was more pronounced for the higher grid ratio. 2D grids provided up to factor of seven lower SPR and 21% better primary transmission than the 1D grid, and their scatter transmission exhibited lower energy dependence. While 2D grids provided up to factor of 2.3 higher CNR improvement, a significant variation in CNR improvement was not observed among different grid pitch and ratios. In summary, grid ratio of 16 and grid pitch of 2 mm can keep SPRs below 0.2 even in high scatter conditions, while keeping primary transmission fractions above 80%, key benefits of the investigated 2D grids in improving image quality of CBCT. However, such grids require precise alignment in source-grid geometry during CBCT acquisitions. This study also implies that 2D grids can provide substantially better scatter suppression and primary transmission than high-performance 1D grids currently available.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Gauss's Law: Cylindrical Symmetry
Transmission-Line Differential Equations
Line Section Model
A circuit representing a line section of length Δx helps in understanding the transmission line parameters. The voltage V(x) and current i(x) are measured from...
Electric Field of Parallel Conducting Plates
Consider a cross-section of a thin, infinite conducting plate having a positive charge. For such a large thin plate, as the thickness of the plate tends to zero, the positive charges lie on the plate's two large faces. Without an external electric field, the...
Plane Electromagnetic Waves I
The EM field is assumed to be a...