Use of an Integrated Low-Flow Anesthetic Vaporizer, Ventilator, and Physiological Monitoring System for Rodents
Published on: July 9, 2020
Use of a Mechanical Ventilator with Respiratory Function Monitoring Provides More Consistent Ventilation during
Deepak Jain1, Carmen D'Ugard2, Ana Aguilar2
1Division of Neonatology, Department of Pediatrics, University of Miami Miller School of Medicine, Jackson Memorial Hospital, Miami, Florida, USA, djain@miami.edu.
Introduction:
Positive pressure ventilation (PPV) with T-Piece and self-inflating bag (SIB) during neonatal resuscitation after birth is associated with variability in ventilation. The use of a ventilator with respiratory function monitoring (RFM) for PPV, however, has not been evaluated.
Objective:
To determine if ventilator + RFM can reduce ventilation variability compared to T-Piece and SIB in a preterm manikin at different combinations of target tidal volume (VT) and lung compliance (CL).
Methods:
Twenty clinicians provided PPV via mask and endotracheal tube (ETT) using SIB, T-Piece, T-Piece + RFM and Ventilator + RFM to a manikin with adjustable lung CL. Three combinations of CL and target VT: Low CL-Low VT, Low CL-High VT and High CL-Low VT were used in a random order.
Results:
The use of ventilator + RFM for PPV via ETT during High CL-Low VT period reduced the proportion of breaths with expiratory VT above target when compared to the other 3 devices (56 ± 35%, 85 ± 20%, 90 ± 25%, 92 ± 12% for ventilator + RFM, T-Piece + RFM, T-Piece, SIB, respectively; p < 0.05). During PPV via both mask and ETT, ventilator + RFM maintained the set Ti and rate, whereas SIB and T-Piece use resulted in higher rates, and T-Piece in higher proportion of breaths with prolonged Ti. During PPV via mask, ventilator + RFM reduced gas leakage compared to other devices.
Conclusion:
In this simulation study, use of a mechanical ventilator with RFM led to an overall improvement in volume targeting at different settings of CL and reduced the gas leak during mask ventilation. The efficacy and safety of using this strategy to neonatal resuscitation in the delivery room needs to be evaluated.
More Related Videos
04:56Laryngeal Mask Airway LMA Placement in a Neonatal Patient Simulator Using a Non-Inflatable Supraglottic Airway SGA
Published on: July 14, 2023
08:58Development of a Neonatal Piglet Acute Lung Injury Model Recreating the Early Environment of Preterm Infant Lungs
Published on: October 31, 2025
Related Concept Videos
Mechanical Ventilation I: Indication and Settings
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Cardiopulmonary Resuscitation II: ACLS Airway Management