Related Experiment Video
Updated: Jan 6, 2026

Force System with Vertical V-Bends: A 3D In Vitro Assessment of Elastic and Rigid Rectangular Archwires
Published on: July 24, 2018
"In Vitro" Study About Variables that Influence in Arch Friction with Conventional and Self-Ligating Brackets
Javier Moyano1, Laia Mases2, Telmo Izeta3
1Department of Orthodontics, School of Dentistry, Universitat Internacional de Catalunya, C/Josep Trueta s/n, 08195 Sant Cugat del Vallés, Barcelona, Spain. javier.moyano@uic.es.
Abstract:
Many advantages have been described surrounding self-ligating (SL) brackets compared to metallic conventional ligating (CL) brackets, such as: Less total treatment time, alignment efficiency, patient comfort, plaque retention, and low friction. The objective of this in vitro simulation was to know the variables that affect arch displacement in CL and SL brackets-active (ASL) and passive (PSL)-and analyze if static friction values are affected by bracket design, arch wire section, kind of ligature, and use of a friction reducer agent (FRA) in a wet state. Larger values of static friction were found in CL with metallic ligature (ML) (8.01 ± 1.08 N/mm) and elastic ligature (EL) (6.96 ± 0.48 N/mm). Lower values were found in PSL brackets combined with FRA (0.58 ± 0.21 N/mm). The study was carried out using different stereographical models of a maxillary upper right quadrant with canine, first and second premolar, and first molar bonded brackets. A section of 25 mm of 0.019 × 0.025" stainless steel arch with a rectangular section (SS) and hybrid section (HY) was inserted into the different bracket models. Static friction values were collected using a universal test machine in wet conditions and testing the effect of a friction reducer agent (FRA). To assure the reliability of the study, different wire combinations were repeated after two weeks by the same operator and a linear analysis of regression was done. Each bracket model analysis-with the different wires, use of the FRA, and comparison among brackets in similar conditions-was done using an ANOVA test with a confidence interval of 95% and comparative Post-Hoc tests (LSD). In this in vitro simulation we found higher static friction values in CL compared to ASL and PSL. In PSL, lower values were achieved. CL brackets using ML showed the highest static friction values with a great variability. In this setting, the use of HY wires did not reduce static friction values in ASL and PSL, while in CL brackets with EL friction the values were reduced significantly. An FRA combined with ASL reduced significantly static friction values but not with PSL. In the case of CL, the FRA effect was higher with SS and better than with HY wires. ML values were similar to ASL static friction. The direct extrapolation of the results might be inaccurate, since all these findings should be tested clinically to be validated.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
07:16Author Spotlight: Development of a Novel Finite Element Analysis Model for Improved Orthognathic Surgical Techniques
Published on: October 20, 2023