Related Experiment Video
Updated: Jan 5, 2026

Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS
Published on: March 14, 2013
On-line in-tube solid phase microextraction coupled to capillary liquid chromatography-diode array detection for the
H D Ponce-Rodríguez1, A A García-Robles2, P Sáenz-González2
1MINTOTA Research Group, Departament de Química Analítica. Facultat de Química. Universitat de València. c/Dr., Moliner 50, 46100, Burjassot, València, Spain; Departamento de Control Químico, Facultad de Química y Farmacia, Universidad Nacional Autónoma de Honduras, Ciudad Universitaria, Tegucigalpa, Honduras.
Abstract:
In-tube solid phase microextraction (IT-SPME) coupled on-line to capillary liquid chromatography with diode array detection provides a simple and fast analytical methodology for the simultaneous quantitation of caffeine and its three primary metabolites (theobromine, paraxanthine and theophylline) in micro samples of serum, saliva and urine matrices. The sample amount required for one analysis was only 2.5 μL of saliva, 6.25 μL of serum or 40 μL of urine, a requirement for its implementation in a hospital laboratory for preterm newborns, where sample availability is a major problem. In standard conditions, 25 μL of diluted saliva or serum (or 100 μL of urine) were processed by IT-SPME in 30 cm of commercially available capillary GC column coated with ZB-FFAP (100% nitroterephthalic modified polyethylene glycol). The retained compounds were desorbed from the IT-SPME capillary by the mobile phase (a gradient mixture of water and methanol) and the separation was carried out in a C18 column (150 mm × 0.5 mm i.d., 5 μm particle size). Analytes eluted before 14 min, at a flow rate of 15 μL min-1, and were detected by absorbance at 275 nm. The calibration graphs presented good linearity (R2 > 0.99), without the presence of matrix effect, and recoveries between 84 and 112% were obtained. Limits of detection (S/N = 3) were 0.1 μg·mL-1 in serum and 0.5 μg·mL-1 in saliva and urine samples, for all compounds, and the intra- and inter-day variation coefficients (n = 3) were between 3 and 17%. Analytical figures of merit were similar to those proposed by other methodologies, but using lower sample volume and a faster and simpler sample treatment and analysis. Paired samples of serum and saliva from preterm newborns treated with caffeine at the pediatric intensive care unit were analyzed by the method, with statistically equivalent results for caffeine concentrations.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
09:11Caffeine Extraction, Enzymatic Activity and Gene Expression of Caffeine Synthase from Plant Cell Suspensions
Published on: October 2, 2018
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...