Related Experiment Video
Updated: Jan 5, 2026

A Multimodal Wide-Field Fourier-Transform Raman Microscope
Published on: December 30, 2025
Micro-Electro-Mechanical System Fourier Transform Infrared (MEMS FT-IR) Spectrometer Under Modulated-Pulsed Light
Ahmed M Othman1, Hussein E Kotb2, Yasser M Sabry1,3
1Faculty of Engineering, Ain-Shams University, Cairo, Egypt.
Abstract:
Miniaturized Fourier transform infrared (FT-IR) spectrometers suffer from limited optical throughput due to their tiny aperture size. Therefore, coherent wideband sources with high brightness can provide an advantage over the wideband thermal radiation sources. However, the former ones are available based on pulsed operation. In this work, we present and study a miniaturized FT-IR spectrometer with pulsed light sources including chopped thermal source, semiconductor optical amplifier, Q-switched and femtosecond mode-locked laser sources. A system model for the FT-IR spectrometer system under a modulated input light source is presented. The model accounts for the relatively high scanning speed of the micro-electro-mechanical system (MEMS) interferometer. The signal-to-noise ratio of the spectrometer, due to the light source modulation, is calculated at different values of modulation repetition rate ranging from 20 Hz to 2 MHz, and duty cycle values ranging from 1% to 50%. An analytical expression for the worst-case repetition rate for the spectrometer system is derived. The model results are verified by experimental measurements showing good agreement with the theoretical expectations. Spectroscopic measurements for CO2 gas with pressure ranging from 300 mbar to 700 mbar are also performed using a high-repetition rate source, and the measured spectra agree with the simulation results demonstrating the utility of the spectrometer.
More Related Videos
10:42Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
Published on: March 22, 2019
10:03Proton Transfer and Protein Conformation Dynamics in Photosensitive Proteins by Time-resolved Step-scan Fourier-transform Infrared Spectroscopy
Published on: June 27, 2014
Related Concept Videos
IR Spectrometers
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....