Related Experiment Video
Updated: Jan 5, 2026

Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
Synthetic CT generation from non-attenuation corrected PET images for whole-body PET imaging
Xue Dong1,2, Tonghe Wang1,2, Yang Lei1
1Department of Radiation Oncology, Emory University, Atlanta, GA, United States of America.
Abstract:
Attenuation correction (AC) of PET/MRI faces challenges including inter-scan motion, image artifacts such as truncation and distortion, and erroneous transformation of structural voxel-intensities to PET mu-map values. We propose a deep-learning-based method to derive synthetic CT (sCT) images from non-attenuation corrected PET (NAC PET) images for AC on whole-body PET/MRI imaging. A 3D cycle-consistent generative adversarial networks (CycleGAN) framework was employed to synthesize CT images from NAC PET. The method learns a transformation that minimizes the difference between sCT, generated from NAC PET, and true CT. It also learns an inverse transformation such that cycle NAC PET image generated from the sCT is close to true NAC PET image. A self-attention strategy was also utilized to identify the most informative component and mitigate the disturbance of noise. We conducted a retrospective study on a total of 119 sets of whole-body PET/CT, with 80 sets for training and 39 sets for testing and evaluation. The whole-body sCT images generated with proposed method demonstrate great resemblance to true CT images, and show good contrast on soft tissue, lung and bony tissues. The mean absolute error (MAE) of sCT over true CT is less than 110 HU. Using sCT for whole-body PET AC, the mean error of PET quantification is less than 1% and normalized mean square error (NMSE) is less than 1.4%. Average normalized cross correlation on whole body is close to one, and PSNR is larger than 42 dB. We proposed a deep learning-based approach to generate sCT from whole-body NAC PET for PET AC. sCT generated with proposed method shows great similarity to true CT images both qualitatively and quantitatively, and demonstrates great potential for whole-body PET AC in the absence of structural information.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET

