Diagnosing sickle cell disease and iron deficiency anemia in human blood by Raman spectroscopy
Wagner Rafael da Silva1, Landulfo Silveira2, Adriana Barrinha Fernandes3
1Universidade Brasil, Estrada Projetada F1, S/N, Fernandópolis, SP, 15600-000, Brazil.
This work proposed the diagnosis of iron deficiency anemia (IDA) and sickle cell disease (SCD) in human blood caused by iron deficiency and hemoglobin S (HbS), which are among the most common anemias, by means of Raman spectroscopy. Whole blood samples from patients diagnosed with IDA and HbS, as well as from normal subjects (HbA), were obtained and submitted to Raman spectroscopy (830 nm, 150 mW, 400-1800 cm-1 spectral range, 4 cm-1 resolution). Difference spectra of IDA-HbA showed spectral features of hemoglobin with less intensity in the IDA, whereas the difference spectra of SCD-HbA showed spectral features of deoxyhemoglobin increased and of oxyhemoglobin decreased in SCD. An exploratory analysis by principal components analysis (PCA) showed that the peaks referred to oxy- and deoxyhemoglobin markedly differentiated SCD and HbA, as well as the increased amount of hemoglobin features in the SCD group, suggesting increased erythropoiesis. The IDA group showed hemoglobin features with lower intensities as well as peaks referred to the iron bonding to the porphyrin ring with reduced intensities when compared to the HbA. Discriminant analysis based on partial least squares (PLS-DA) and PCA (PCA-DA) showed that the IDA and SCD anemias could be discriminated from the HbA spectra with 95.0% and 93.8% of accuracy, for the PLS and PCA respectively, with sensitivity/specificity of 93.8%/95.7% for the PLS-DA model. The iron depletion and the sickling of erythrocytes could be identified by Raman spectroscopy and a spectral model based on PLS accurately discriminated these IDA and SCD samples from the normal HbA.
This work proposed the diagnosis of iron deficiency anemia (IDA) and sickle cell disease (SCD) in human blood caused by iron deficiency and hemoglobin S (HbS), which are among the most common anemias, by means of Raman spectroscopy. Whole blood samples from patients diagnosed with IDA and HbS, as well as from normal subjects (HbA), were obtained and submitted to Raman spectroscopy (830 nm, 150 mW, 400-1800 cm-1 spectral range, 4 cm-1 resolution). Difference spectra of IDA-HbA showed spectral features of hemoglobin with less intensity in the IDA, whereas the difference spectra of SCD-HbA showed spectral features of deoxyhemoglobin increased and of oxyhemoglobin decreased in SCD. An exploratory analysis by principal components analysis (PCA) showed that the peaks referred to oxy- and deoxyhemoglobin markedly differentiated SCD and HbA, as well as the increased amount of hemoglobin features in the SCD group, suggesting increased erythropoiesis. The IDA group showed hemoglobin features with lower intensities as well as peaks referred to the iron bonding to the porphyrin ring with reduced intensities when compared to the HbA. Discriminant analysis based on partial least squares (PLS-DA) and PCA (PCA-DA) showed that the IDA and SCD anemias could be discriminated from the HbA spectra with 95.0% and 93.8% of accuracy, for the PLS and PCA respectively, with sensitivity/specificity of 93.8%/95.7% for the PLS-DA model. The iron depletion and the sickling of erythrocytes could be identified by Raman spectroscopy and a spectral model based on PLS accurately discriminated these IDA and SCD samples from the normal HbA.
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...