Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
Published on: September 21, 2011
Purification of ADCs by Hydrophobic Interaction Chromatography
Calvin L Becker1, Robert J Duffy2, Jorge Gandarilla3
1Abbvie Inc., North Chicago, IL, USA. calvin.becker@abbvie.com.
Abstract:
Antibody-drug conjugate (ADC) in vitro potency has been shown to be dependent on drug load, with higher drug load providing lower IC50 values. However, in vivo potency is affected by intrinsic biological effects as well, such as plasma clearance, dose-limiting toxicity, etc. Developing a preparative HIC process for ADC purification to isolate species with a specific drug loading involves several steps including conjugation optimization, resin selection, solubility studies gradient screening, and step gradient development (buffer selection). In this chapter, the rationale and general considerations for developing a preparative hydrophobic interaction chromatography (HIC) method are described for isolation of an example ADC with specific drug load, e.g., two monomethyl auristatin E (MMAE) payloads (E2).