Related Experiment Video
Updated: Jan 5, 2026

Simulation of Human-induced Vibrations Based on the Characterized In-field Pedestrian Behavior
Published on: April 13, 2016
Application of tuned liquid column ball damper (TLCBD) for improved vibration control performance of multi-storey
Muhammad Tanveer1, Muhammad Usman1, Imdad Ullah Khan1
1School of Civil & Environmental Engineering, National University of Science and Technology (NUST), Sector H-12, Islamabad, Pakistan.
Abstract:
Tuned liquid column ball damper (TLCBD) is a passive control device used for controlling the building vibrations induced from wind or earthquakes. TLCBD is a modified form of conventional tuned liquid column damper (TLCD). This paper studies the effect of TLCBD on the four-storey steel frame structure. The performance of the TLCBD is also compared with conventional TLCD. The analytical model of both TLCD and TLCBD is presented here. The effectiveness of these analytical models is examined experimentally by series of shaking table tests under different excitation levels including harmonic loadings and seismic excitations. In TLCBD, the vibration is reduced significantly as compared to TLCD by using steel ball as a moving orifice. The difference in diameter of steel ball and tube, containing the liquid column, acts as an orifice which moves with the movement of the ball. This moving orifice phenomenon enhanced the vibration reduction effect by resisting the water motion in the TLCBD. Root mean square (RMS) and peak values of acceleration were calculated for each loading and each storey of uncontrolled and controlled structures. Comparison of the time histories of controlled and uncontrolled structures for different loadings is also reported. Results indicate that the TLCBD is more effective in the earthquake scenarios as compared to the harmonic excitations. The TLCBD controls the vibration of the primary structure significantly in vibration reduction.
Related Concept Videos
Types of Building Separation Joints
Volume-change joints address the effects of expansion and contraction due to temperature and moisture variations. They are strategically placed at discontinuities in a building's mass where cracking is most likely and are spaced about 150 to 200...
Design of Columns under an Eccentric Load
Types of Damping
Design of Columns under a Centric Load
Euler's formula is applicable under the assumption that the column is a perfect, straight, homogenous prism, and it is operating...
Method of Superposition
When applying the method of superposition, each type of load—whether...
Posttensioned Masonry Walls
Post-tensioned masonry walls use high-strength steel rods or flexible tendons to enhance the strength and efficiency of masonry structures. These elements are securely anchored to the foundation and extend vertically either within the cores of the masonry units or between the masonry wythes. The construction process involves building the wall with these tensioning elements in place and allowing the mortar to fully cure.
Following the curing process, the tensioning begins. Steel rods are...

