Related Experiment Video
Updated: Jan 5, 2026

Characterization of Metabolic Status in Nonhuman Primates with the Intravenous Glucose Tolerance Test
Published on: November 13, 2016
Results of a Study Comparing Glycated Albumin to Other Glycemic Indices
Cyrus V Desouza1, Richard G Holcomb2, Julio Rosenstock3
1University of Nebraska Medical Center, Omaha, Nebraska.
Context:
Intermediate-term glycemic control metrics fulfill a need for measures beyond hemoglobin A1C.
Objective:
Compare glycated albumin (GA), a 14-day blood glucose measure, with other glycemic indices.
Design:
24-week prospective study of assay performance.
Setting:
8 US clinics.
Participants:
Subjects with type 1 (n = 73) and type 2 diabetes (n = 77) undergoing changes to improve glycemic control (n = 98) or with stable diabetes therapy (n = 52).
Interventions:
GA, fructosamine, and A1C measured at prespecified intervals. Mean blood glucose (MBG) calculated using weekly self-monitored blood glucose profiles.
Main Outcome Measures:
Primary: Pearson correlation between GA and fructosamine. Secondary: magnitude (Spearman correlation) and direction (Kendall correlation) of change of glycemic indices in the first 3 months after a change in diabetes management.
Results:
GA was more concordant (60.8%) with changes in MBG than fructosamine (55.5%) or A1C (45.5%). Across all subjects and visits, the GA Pearson correlation with fructosamine was 0.920. Pearson correlations with A1C were 0.655 for GA and 0.515 for fructosamine (P < .001) and with MBG were 0.590 and 0.454, respectively (P < .001). At the individual subject level, Pearson correlations with both A1C and MBG were higher for GA than for fructosamine in 56% of subjects; only 4% of subjects had higher fructosamine correlations with A1C and MBG. GA had a higher Pearson correlation with A1C and MBG in 82% and 70% of subjects, respectively.
Conclusions:
Compared with fructosamine, GA correlates significantly better with both short-term MBG and long-term A1C and may be more useful than fructosamine in clinical situations requiring monitoring of intermediate-term glycemic control (NCT02489773).
More Related Videos
Related Concept Videos
Oral Hypoglycemic Agents: Glinides
Dipeptidyl Peptidase 4 Inhibitors
Oral Hypoglycemic Agents: α-Glucosidase Inhibitors
Acarbose and miglitol are...
Glucagon-like Receptor Agonists
GLP-1, when administered in high doses intravenously, triggers insulin secretion, inhibits glucagon release, slows gastric emptying, reduces food intake, and restores normal insulin secretion. However, its rapid inactivation by...

