Evaluation of ventricular-arterial coupling by impedance cardiography in healthy volunteers
Ricardo D Olano1, Walter G Espeche1,2, Martin R Salazar1,2,3,4
1Unidad de Enfermedades Cardiometabólicas, Servicio de Clínica Médica, Hospital Gral. San Martín, La Plata, Argentina.
Background:
The interplay between cardiac function and the arterial system is currently defined as ventricular-arterial coupling (VAC) and it is an expression of global cardiovascular efficiency. VAC involves a variety of complex interactions between the heart and the vasculature. A basic index of VAC is the ratio of effective arterial elastance (Ea)/ end-systolic elastance (Ees). While this is often done with echocardiography, obtaining Ea/Ees using impedance cardiography is feasible, although this possibility has not been explored so far.
Objective:
The aim of this study was to compare the Ea/Ees values obtained using echocardiography and impedance cardiography.
Approach:
Two independent operators estimated Ea/Ees in 91 (41 ± 14 years old, women 51%) untreated apparently healthy individuals using (1) Doppler echocardiography with the single-beat method developed by Chen et al (2001 J. Am. Coll. Cardiol. 38 2028-34); and (2) data provided by impedance cardiography. The differences between Ea/Ees values were compared and correlation between both methods was estimated.
Main Results:
Although Ea and Ees values calculated by impedance cardiography were lower than those estimated by echocardiography (-0.201 ± 0.457 mmHg ml-1 and -0.193 ± 0.413 mmHg ml-1), Ea/Ees ratio values were similar. Thus, there was no significant difference between the mean values of Ea/Ees estimated by impedance cardiography or echocardiography (Ea/Ees impedance cardiography - Ea/Ees echocardiography = -0.015 ± 0.096, p = 0.150). Ea/Ees values calculated by both methods were highly correlated (r = 0.85, p < 0.001), as well as the pre-ejection and left ventricular ejection time (r = 0.83 and r = 0.91, respectively).
Significance:
In healthy individuals, estimation of Ea/Ees by impedance cardiography yielded similar values to those obtained using echocardiography.
More Related Videos
10:21Evaluation of Hydration Status by Bioelectrical Impedance Vector Analysis in Patients with Ischemic Heart Disease Undergoing Exercise Stress Test
Published on: September 22, 2023
08:19Electrophysiological Assessment of Murine Atria with High-Resolution Optical Mapping
Published on: February 22, 2018
Related Concept Videos
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Electrophysiology of Normal Cardiac Rhythm
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for: