Related Experiment Video
Updated: Jan 4, 2026

PET and MRI Guided Irradiation of a Glioblastoma Rat Model Using a Micro-irradiator
Published on: December 28, 2017
Segmentation of gliomas in 18F-fluorocholine PET/CT. A multiapproach study
A M García Vicente1, J Pérez-Beteta2, G A Jiménez Londoño1
1Nuclear Medicine Department, Hospital General Universitario de Ciudad Real, Ciudad Real, España.
Aim:
Our aim was two-fold, to study the interobserver agreement in tumour segmentation and to search for a reliable methodology to segment gliomas using 18F-fluorocholine PET/CT.
Methods:
25 patients with glioma, from a prospective and non-randomized study (Functional and Metabolic Glioma Analysis), were included.Interobserver variability in tumour segmentation was assessed using fixed thresholds. Different strategies were used to segment the tumours. First, a semi-automatic tumour segmentation was performed, selecting the best SUVmax-% threshold for each lesion. Next we determined a variable SUVmax-% depending on the SUVmax. Finally a segmentation using a fixed SUVmax threshold was performed. To do so, a sampling of 10 regions of interest (ROI of 2.8cm2) located in the normal brain was performed. The upper value of the sample mean SUVmax±3 SD was used as cut-off. All procedures were tested and classified as effective or not for tumour segmentation by two observer's consensus.
Results:
In the pilot segmentation, the mean±SD of SUVmax, SUVmean and optimal SUVmax-% threshold were: 3.64±1.77, 1.32±0.57 and 21.32±8.39, respectively. Optimal SUVmax-% threshold showed a significant association with the SUVmax (Pearson=-0.653, p=.002). However, the linear regression model for the total sample was not good, that supported the division in two homogeneous groups, defining two formulas for predicting the optimal SUVmax-% threshold. As to the third procedure, the obtained value for the mean SUVmax background+3 SD was 0.33. This value allowed segmenting correctly a significant fraction of tumours, although not all.
Conclusion:
A great interobserver variability in the tumour segmentation was found. None of the methods was able to segment correctly all the gliomas, probably explained by the wide tumour heterogeneity on 18F-fluorocholine PET/CT.
More Related Videos
09:58Semi-quantitative Assessment Using [18F]FDG Tracer in Patients with Severe Brain Injury
Published on: November 9, 2018
10:02Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography FDG-PET/CT
Published on: May 2, 2012