Related Experiment Video
Updated: Jan 4, 2026

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Aligning retention time shifts in HPLC three-dimensional spectra by icoshift approach combined with data arrangement
Xiang-Zhi Zhang1, Na Feng1, Ai-Jun Ma1
1School of Biotechnology and Health Sciences, Wuyi University, Jiangmen, P.R. China.
Abstract:
High-performance liquid chromatography coupled with photodiode array detection has been extensively applied in many fields and the peaks among the analyzed samples can be shifted due to the variations of instrumental and experimental conditions. In multivariate analysis, retention time alignment is an important pretreatment step. Hence, the shifted peaks in high-performance liquid chromatography coupled with photodiode array detection three-dimensional spectra should be aligned for further analysis. Being motivated by this purpose, the interval correlated shifting method combined with the proposed data arrangement methods are recommended and employed on high-performance liquid chromatography coupled with photodiode array detection data as a demonstration. We validate the alignment performance of the proposed method through comparison the consistency of the retention time before and after alignment. The obtained results demonstrated that the proposed method is capable of successful aligning the employed data. Additionally, the interval correlated shifting method combined with the data arrangement modes is implemented in an easy-to-use graphical user interface environment and so can be operated easily by users not familiar with programming languages.
Related Concept Videos
NMR Spectroscopy: Chemical Shift Overview
For instance, the proton...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
2D NMR: Heteronuclear Single-Quantum Correlation Spectroscopy (HSQC)
High-Performance Liquid Chromatography: Elution Process