Related Experiment Video
Updated: Jan 4, 2026

Thermal Measurement Techniques in Analytical Microfluidic Devices
Published on: June 3, 2015
Analysis and Simulation of Forcing the Limits of Thermal Sensing for Microbolometers in CMOS-MEMS Technology
Hasan Göktaş1, Fikri Serdar Gökhan2
1Department of Electrical and Electronic Engineering, Harran University, Şanlıurfa 63000, Turkey. hgoktas.gwu@gmail.com.
Abstract:
Room-temperature highly sensitive microbolometers are becoming very attractive in infrared (IR) sensing with the increase in demand for the internet of things (IOT), night vision, and medical imaging. Different techniques, such as building extremely small-scale devices (nanotubes, etc.) or using 2D materials, showed promising results in terms of high sensitivity with the cost of challenges in fabrication and low-noise readout circuit. Here, we propose a new and simple technique on the application of joule heating on a clamped-clamped beam without adding any complexity. It provides much better uniformity in temperature distribution in comparison to conventional joule heating, and this results in higher thermal stresses on fixed ends. This consequently brings around 60.5× improvement in the overall temperature sensitivity according to both theory and COMSOL (multiphysics solver). The sensitivity increased with the increase in the stiffness constant, and it was calculated as 134 N/m for a device with a 60.5× improvement. A considerable amount of decrease in the operation temperature (36× below 383 K and 47× below 428 K) was achieved via a new technique. That's why the proposed solution can be used either to build highly reliable long-term devices or to increase the thermal sensitivity.
More Related Videos
09:01High-resolution Thermal Micro-imaging Using Europium Chelate Luminescent Coatings
Published on: April 16, 2017
04:09Demonstrating the Simplicity and In Situ Temperature Monitoring of the Mechanochemical Synthesis of Metal Chalcogenides Suitable for Thermoelectrics
Published on: August 30, 2024
Related Concept Videos
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in temperature (ΔT) is 55...
Biasing of Metal-Semiconductor Junctions
In Schottky junctions, where the semiconductor is n-type, applying a positive voltage to the metal relative to the semiconductor reduces its Fermi...