Accurate modelling of the retention behaviour of peptides in gradient-elution hydrophilic interaction liquid

Liana S Roca1, Suzan E Schoemaker2, Bob W J Pirok1

  • 1Van 't Hoff Institute for Molecular Sciences, Science Park 904, 1098 XH Amsterdam, the Netherlands; Centre for Analytical Science Amsterdam, Science Park 904, 1098 XH Amsterdam, the Netherlands.

The applicability of models to describe peptide retention in hydrophilic interaction liquid chromatography (HILIC) was investigated. A tryptic digest of bovine-serum-albumin (BSA) was used as a test sample. Several different models were considered, including adsorption, mixed-mode, exponential, quadratic and Neue-Kuss models. Gradient separations were performed on three different HILIC stationary-phases under three different mobile-phase conditions to obtain model parameters. Methods to track peaks for specific peptides across different chromatograms are shown to be essential. The optimal mobile-phase additive for the separation of BSA digest on each of the three columns was selected by considering the retention window, peak width and peak intensity with mass-spectrometric detection. The performance of the models was investigated using the Akaike information criterion (AIC) to measure the goodness-of-fit and evaluated using prediction errors. The F-test for regression was applied to support model selection. RPLC separations of the same sample were used to test the models. The adsorption model showed the best performance for all the HILIC columns investigated and the lowest prediction errors for two of the three columns. In most cases prediction errors were within 1%.

Related Concept Videos

High-Performance Liquid Chromatography: Elution Process01:05

High-Performance Liquid Chromatography: Elution Process

In High-Performance Liquid Chromatography (HPLC), the elution process is critical to the separation of analytes and the quality of chromatographic results. Elution describes how compounds move through the column and separate based on their interactions with the mobile and stationary phases. This process determines the resolution, peak shape, and retention times in the chromatogram, which are essential for identifying and quantifying components in complex mixtures. Understanding the elution...
1.3K
Ion-Exchange Chromatography01:09

Ion-Exchange Chromatography

Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...
1.7K
High-Performance Liquid Chromatography: Introduction01:11

High-Performance Liquid Chromatography: Introduction

High-performance liquid chromatography(HPLC), formerly referred to as High-pressure liquid chromatography, is a powerful technique used to separate, identify, and quantify components in complex mixtures. The term "high pressure" refers to using high pressure to push the liquid mobile phase through the tightly packed columns.
In HPLC, two phases play a critical role in the separation process:
3.2K
Chromatographic Methods: Terminology01:18

Chromatographic Methods: Terminology

Chromatography is an analytical technique widely used in fields such as chemistry, biology, environmental science, and pharmaceuticals to separate the components of a mixture and identify substances between them. The process of chromatography is based on the interactions between two distinct phases: the stationary phase and the mobile phase. The stationary phase is fixed in place by a supporting material, while the mobile phase moves over it, carrying the solutes. As the mobile phase travels,...
3.6K
Size-Exclusion Chromatography01:08

Size-Exclusion Chromatography

In size-exclusion chromatography (SEC), also known as molecular-exclusion or gel-permeation chromatography, molecules are separated based on their sizes. This technique is important for separating large molecules such as polymers and biomolecules. The two classes of micron-sized stationary phases encountered in SEC are silica particles and cross-linked polymer resin beads. Both materials are porous, but their pore sizes vary significantly.
Silica particles offer advantages such as rigidity,...
1.6K
High-Performance Liquid Chromatography: Instrumentation00:57

High-Performance Liquid Chromatography: Instrumentation

High-performance liquid chromatography, or HPLC, is an analytical technique that separates liquid samples under high pressures. An HPLC instrument consists of glass bottles for storing solvents called mobile phase reservoirs. HPLC-grade solvents are used to maintain high purity, and the dissolved gases are removed using a degasser, such as a vacuum pumping system or sparging with helium. The solvents are then pumped into the analytical column using a screw-driven syringe or reciprocating pumps.
2.8K