Toward the Development of a Wearable Optical Respiratory Sensor for Real-Time Use
Alejo Chavez-Gaxiola1, Zachary Fisher1, Jeffrey T La Belle2
1School of Biological and Health Systems Engineering, Arizona State University, Tempe, AZ 85287.
Abstract:
Respiration rate is an important vital sign that can provide insight into a patient's status and health progression. This information is used from critical care to sports and human performance evaluation. The current state of the art has demonstrated effectiveness in monitoring respiration rate with the use of wearable sensors. However, their form factor, which refers to the embodiment of approach, size, and shape, makes it difficult to implement within a longterm monitoring setting. Problems relating to form factor, such as compliance, are a major issue in collecting useful and actionable data, because they directly impact comfort and ease of wear. We present a new approach based on an optical computer mouse sensor that can be rendered into a slim, wearable device without the need for a harness or shirt to hold the sensor in place. Its main objective is to achieve similar or better readings than those of the state of the art while reducing the overall size and thus, improve compliance by making it easier, more comfortable to wear. The principle of operation of the sensor allows for enhanced signal and computational noise reduction for movement artifacts. The sensor was tested to determine its limits of detection and was calibrated to expected distance of movement. Then, observations were made under normal breathing conditions, apnea, deep breathing, and hyperventilation covering a spectrum of 0 to 45 breathings per minute (BPM). The performance of the device was described by using the mean average error which was 0.37 and 0.83 under deep breathing and hyperventilation, respectively. Testing revealed that the device produces the best results when worn over the diaphragm and that its readings are comparable to the industry gold standard. The future version we are developing incorporates a slimmer, lighter design, Bluetooth data communication to remove leads and wires, adhesive electrodes and a reusable adhesive that is also waterproof.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...