Related Experiment Video
Updated: Jan 4, 2026

Multifractal Spectrum Analysis for Assessing Pulmonary Nodule Malignancy
Published on: January 10, 2025
Solid Indeterminate Nodules with a Radiological Stability Suggesting Benignity: A Texture Analysis of Computed
Bruno Max Borguezan1, Agnaldo José Lopes1,2, Eduardo Haruo Saito1,3
1Post-graduate Programme in Medical Sciences, School of Medical Sciences, State University of Rio de Janeiro, Rio de Janeiro, Brazil.
Background:
The number of incidental findings of pulmonary nodules using imaging methods to diagnose other thoracic or extrathoracic conditions has increased, suggesting the need for in-depth radiological image analyses to identify nodule type and avoid unnecessary invasive procedures.
Objectives:
The present study evaluated solid indeterminate nodules with a radiological stability suggesting benignity (SINRSBs) through a texture analysis of computed tomography (CT) images.
Methods:
A total of 100 chest CT scans were evaluated, including 50 cases of SINRSBs and 50 cases of malignant nodules. SINRSB CT scans were performed using the same noncontrast enhanced CT protocol and equipment; the malignant nodule data were acquired from several databases. The kurtosis (KUR) and skewness (SKW) values of these tests were determined for the whole volume of each nodule, and the histograms were classified into two basic patterns: peaks or plateaus.
Results:
The mean (MEN) KUR values of the SINRSBs and malignant nodules were 3.37 ± 3.88 and 5.88 ± 5.11, respectively. The receiver operating characteristic (ROC) curve showed that the sensitivity and specificity for distinguishing SINRSBs from malignant nodules were 65% and 66% for KUR values >6, respectively, with an area under the curve (AUC) of 0.709 (p < 0.0001). The MEN SKW values of the SINRSBs and malignant nodules were 1.73 ± 0.94 and 2.07 ± 1.01, respectively. The ROC curve showed that the sensitivity and specificity for distinguishing malignant nodules from SINRSBs were 65% and 66% for SKW values >3.1, respectively, with an AUC of 0.709 (p < 0.0001). An analysis of the peak and plateau histograms revealed sensitivity, specificity, and accuracy values of 84%, 74%, and 79%, respectively.
Conclusions:
KUR, SKW, and histogram shape can help to noninvasively diagnose SINRSBs but should not be used alone or without considering clinical data.
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...