Related Experiment Video
Updated: Jan 4, 2026

Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
TAVI Using a Self-Expandable Device for Aortic Regurgitation Following LVAD Implantation
Harun Sarwari1, Andreas Schaefer1, Markus J Barten1
1Department of Cardiovascular Surgery, University Heart Center Hamburg, Hamburg, Germany.
Abstract:
Background In patients treated by left ventricular assist device (LVAD), aortic regurgitation (AR) may occur. Secondary surgery to correct AR is considered high risk. Case Description We report a case of severe AR following LVAD implantation in a patient who was subsequently treated by transcatheter aortic valve implantation (TAVI) using the latest generation self-expandable transcatheter heart valve (THV) (Boston Scientific Acurate neo, size M [Boston Scientific, Marlborough, Massachusetts, United States]). TAVI followed modified procedural protocol and sizing algorithm. THV implantation without prior balloon aortic valvuloplasty resulted in an adequate valve function without leakage. Conclusion This THV may be particularly well suited for TAVI subsequent to LVAD implantation if modified sizing and deployment considerations are appreciated.