Intraoperative Indocyanine Green Near-Infrared Angiography for Redo Valve Replacement
Brian Solomon1, Andreas Sarantopoulos1, Thomas Caranasos1
1Department of Cardiothoracic Surgery, Naples Community Hospital Healthcare System, Naples, Florida, United States.
Background:
Redo aortic interventions after failed transcatheter aortic valve replacement (TAVR) are challenging, particularly with low coronary heights and dense frame ingrowth.
Case Description:
An 83-year-old woman with prior TAVR developed severe prosthetic stenosis. Surgical Resection of Prosthetic Valve Leaflets Under Direct Vision (SURPLUS) with implantation of a balloon-expandable aortic valve and intraoperative low-dose indocyanine green (ICG) near-infrared (NIR) angiography was performed. Real-time NIR imaging confirmed symmetric coronary opacification. The valve was well seated with improved ejection fraction (60-65%), and recovery was uneventful.
Conclusion:
SURPLUS with ICG-NIR angiography ensured coronary patency and safe hemodynamic restoration.
More Related Videos
Related Concept Videos
Green Algae
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...