Related Experiment Video
Updated: Sep 22, 2026

Transoral Robotic Total Thyroidectomy and Bilateral Central Regional Lymph Node Dissection for Papillary Thyroid Carcinoma
Published on: September 15, 2023
Port-Site Implantation Diagnosed by Iodine-131 Post-Ablation Single-Photon Emission Tomography-Computed Tomography
Mi Ra Kim1, Sunmi Jo2, Hye-Kyung Shim3
1Department of Otorhinolaryngology-Head and Neck Surgery, Haeundae Paik Hospital, Inje University College of Medicine, Busan, South Korea.
Abstract:
BACKGROUND Robotic thyroidectomy using remote access approaches is currently regarded as the optimal surgical protocol for highly selected patients. This approach has excellent cosmetic outcomes compared with conventional open transcervical thyroidectomy. Although the remote access approach offers significant benefits, it can cause complications associated with the large working space required for surgery. Such complications can lead to unusual imaging findings. CASE REPORT We report a case of a 37-year-old woman with thyroid cancer who underwent robotic thyroidectomy and demonstrated unusual port-site implantation findings on post-treatment iodine-131 whole-body scintigraphy and single-photon emission computed tomography-computed tomography. Evaluation of stimulated thyroglobulin and additional imaging studies did not reveal any remarkable findings. Through a multidisciplinary discussion, we discovered that the bag had developed a tear during specimen retrieval. Our patient was administered a therapeutic dose of radioiodine, which accumulated within the target area and successfully ablated the implanted tissue. Follow-up imaging and biochemical studies were normal after a follow-up period of 7 years. CONCLUSIONS Port-site seeding is a rare and unexpected surgical complication; however, it can be treated with radioiodine therapy involving a therapeutic dose. Meticulous surgical manipulation is essential to prevent port-site implantation related to spillage and tearing of thyroid or cancer tissue. Awareness and identification of these rare complications, which manifest as unusual imaging findings, are critical for improving the accuracy of interpretation.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET

