Related Experiment Video
Updated: Jan 3, 2026

On the Preparation and Testing of Fuel Cell Catalysts Using the Thin Film Rotating Disk Electrode Method
Published on: March 16, 2018
Performance experimental data of a polymer electrolyte fuel cell considering the variation of the relative humidity
Mayken Espinoza-Andaluz1, Jordy Santana2, Tingshuai Li3
1ESPOL Polytechnic, Escuela Superior Politécnica del Litoral, ESPOL, Facultad de Ingeniería Mecánica y Ciencias de la Producción, Centro de Energías Renovables y Alternativas, Campus Gustavo Galindo, Km. 30.5 Vía Perimetral, P.O. Box 09-01-5863, Guayaquil, Ecuador.
Abstract:
The data collected in this article is based on a performance test of a polymer electrolyte fuel cell (PEFC). The behavior the different parameters of a PEFC is analyzed considering different aspects relative to the inlet gases temperatures. The fuel cell was evaluated by means of a current sweep at different percentages of relative humidity between the feed gas and the cell. The relative humidity values were established by means of the temperature setting. The data presented show the experimental response of the cell in real time, which can be used to perform a depth analysis or they can be a starting point for material and performance investigation. In addition, charts presenting the voltage and power density behavior as a function of the volumetric flows of the anode (H2) as well as cathode (O2). The data presented in this article are originally from our research performed in [1].