Related Experiment Video
Updated: Jan 3, 2026

Author Spotlight: Assessment of Cardiac Output Calculation by Thermodilution in Pigs for Effective Perfusion Flow During EVLP
Published on: June 28, 2024
Indirect Calorimetry Overestimates Oxygen Consumption in Young Children: Caution is Advised Using Direct Fick Method
Theodor S Sigurdsson1,2, Lars Lindberg3
1Department of Pediatric Anesthesia and Intensive Care, Children's Hospital, Skåne University Hospital, Lund, Sweden. theodors@landspitali.is.
Indirect calorimetry overestimates oxygen consumption in pediatric patients compared to the reverse Fick method. This significant overestimation means indirect calorimetry is not interchangeable with the reverse Fick method for cardiac output studies in children.
Area of Science:
- Cardiology
- Pediatric Medicine
- Physiology
Background:
- The direct Fick method is a gold standard for cardiac output estimation, relying on accurate oxygen consumption measurement.
- Indirect calorimetry is frequently used but has shown overestimation of oxygen consumption in adults.
- Accurate oxygen consumption is critical, as minor errors can lead to false cardiac output estimations.
Purpose of the Study:
- To compare oxygen consumption determination between indirect calorimetry and the reverse Fick method in pediatric patients.
- To assess the interchangeability of these methods for cardiac output studies in young children.
Main Methods:
- Prospective, single-center, observational method comparison study.
- Included 42 pediatric patients (mean age 352 days) undergoing cardiac surgery.
- Measured oxygen consumption using both indirect calorimetry and the reverse Fick method.
Main Results:
- Indirect calorimetry overestimated oxygen consumption by 14.7% compared to the reverse Fick method (49.9 vs. 43.5 ml/min).
- A significant bias (6.5 ml/min) and large percentage error (47.7%) were observed between the methods.
- Limits of agreement were wide (-15.7 to 28.7 ml/min), indicating poor agreement.
Conclusions:
- Indirect calorimetry and the direct Fick method are not interchangeable for cardiac output estimation in pediatric patients.
- These methods should be used with caution as reference methods in pediatric cardiac output comparison studies.
- Further research is needed to validate accurate oxygen consumption measurement techniques in children.
More Related Videos
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...

