Evaluation of Containment Ventilated Enclosure Performance in Absence of Negative Pressure Containment Secondary
1Professional Compounding Centers of America, Houston, Texas. Chutson@pccarx.com.
Abstract:
The purpose of this study was to evaluate the efficacy of a containment ventilated enclosure on preventing powder exposure to surrounding areas during a high-particle generating compounding procedure in absence of a negative pressure compounding secondary engineering control. Air samples were collected under actual compounding conditions to assess compounder and room exposure to estradiol powder. Samples were collected from several locations. The entire compounding process took place in a containment ventilated enclosure after assessing performance characteristics via velocity and smoke sampling. The particle generating compounding process consisted of weighing, multiple transfers, trituration, and capsule filling. Compounding procedures were performed by three different compounders. The laboratory detection limit for estradiol was determined, and collection parameters were targeted to ensure adequate samples were obtained to prevent false negative results. Sampling time for each compounder ranged from 24 minutes to 38 minutes. All samples collected during compounding procedures showed less than detectable amounts of estradiol. Observation of the compounding procedure showed notable potential particle generation during the compounding procedure, including spills and vigorous jostling of compounding equipment prior to encapsulation. Despite a significant potential for particulate generation inside the containment ventilated enclosure, no estradiol was detected outside of the enclosure. These findings suggest that powder chemical exposure to the compounder is minimal when using a properly certified containment ventilated enclosure. The findings also show a lack of exposure of the room to aerosolized estradiol even when using a neutral containment secondary engineering control.
Related Concept Videos
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation I: Indication and Settings
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
PPE Use in Healthcare Settings II: Doffing