Related Experiment Video
Updated: Aug 19, 2026

Use of Electromagnetic Navigational Transthoracic Needle Aspiration (E-TTNA) for Sampling of Lung Nodules
Published on: May 23, 2015
Technique and guidelines for needle localization biopsy of nonpalpable lesions of the breast
1Department of Surgery, University of Virginia, Charlottesville 22908.
Abstract:
The advances made in mammography, including its accuracy, safety and publicity, will lead to an increasing number of biopsies of the breast after needle localization. The surgeon must carefully evaluate the mammograms and orient the location of the tip of the wire with respect to the mammographic abnormality and the exact location within the breast. The technique described has been used in more than 600 instances. It has led to the detection of cancer in 20 per cent of nonpalpable suspicious mammographic findings. It is well tolerated, readily accomplished, cost effective and accurate.
More Related Videos
07:51The Application of 1% Methylene Blue Dye As a Single Technique in Breast Cancer Sentinel Node Biopsy
Published on: June 1, 2019
06:42Optimization of Breast Biopsy and Mastectomy Sample Collection Procedures for Biobanking, Personalized Medicine, and Research Applications
Published on: September 2, 2025