Related Experiment Video
Updated: Jan 3, 2026

Diffuse Reflectance Infrared Spectroscopic Identification of Dispersant/Particle Bonding Mechanisms in Functional Inks
Published on: May 8, 2015
Incorporating Non-NIR Absorbing Agent into Packed Powder Samples in Diffuse Reflectance NIR Measurement to Improve
Yoonjeong Lee1, Pham Khac Duy1, Hoeil Chung1
1Department of Chemistry and Research Institute for Convergence of Basic Science , Hanyang University , Seoul 04763 , Republic of Korea.
Abstract:
A strategy to improve accuracy of near-infrared (NIR) quantitative analysis of powder samples by alleviating the subsampling problem is demonstrated. The approach is to increase spectroscopic sampling volume for more accurate representation of its composition by filling the void space in a packed sample with liquid to reduce differences in refractive index between particle and unoccupied space. By this way, NIR radiation can propagate deeper into the packed powder due to decreased degree of reflection at the interfaces, leading to greater sampling volume. Perfluorohexane (PFH) was chosen as the space-filling liquid since it does not readily absorb NIR radiation and does not disintegrate sample particles due to its strong hydrophobicity. For evaluation, binary mixtures composed of ambroxol and lactose at different concentrations were prepared, and their diffuse reflectance spectra were collected in two ways: conventional direct powder measurement and PFH-incorporated powder measurement. The accuracy of ambroxol concentration determination improved in the PFH-incorporated measurement due to acquisition of more composition-representative spectra by the greater sampling volume. Also, the sample morphology did not change in PFH medium based on XRD analysis. In parallel, Monte Carlo simulation was executed to track NIR photons in the samples and explain the improved accuracy. Improvement in accuracy was also realized when analyzing real pharmaceutical samples containing an active pharmaceutical ingredient in granular form, demonstrating expandability of the proposed scheme.
Related Concept Videos
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
IR Spectrometers
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences