Related Experiment Video
Updated: Jan 3, 2026

Analysis of Cerebral Vasospasm in a Murine Model of Subarachnoid Hemorrhage with High Frequency Transcranial Duplex Ultrasound
Published on: June 3, 2021
Intracranial venous sinus stenosis: hemodynamic assessment with two-dimensional parametric parenchymal blood flow
Zayed Almadidy1, Denise Brunozzi1, Jessica Nelson2
1Neurosurgery, University of Illinois at Chicago, Chicago, Illinois, USA.
Objective:
Intracranial venous sinus stenosis (IVSS) is the most common finding associated with idiopathic intracranial hypertension. A pressure gradient >8-10 mm Hg across the stenosis is considered hemodynamically significant, and typically responds to endovascular stent treatment. Here we assess the venous hemodynamics with two-dimensional (2D) parametric parenchymal blood flow software (Siemens-Healthineers, Forchheim, Germany) and its ability to predict significant IVSS.
Methods:
Patients with IVSS treated at our institution between 2013 and 2018 were retrospectively reviewed. Measurements of contrast transit time on DSA were calculated with 2D parametric parenchymal blood flow software. Values were obtained proximally and distally to the stenotic region. Venous Stenosis Index (VSI) was defined as the ratio of the area under the curve (AUC) in the pre-stenotic vessel to the AUC in the post-stenotic vessel. VSI was compared between the stenotic and control groups at baseline, and before and after stent deployment in the stenotic group. The accuracy of VSI was assessed using the non-parametric receiver operating characteristic (ROC) curve.
Results:
11 patients with IVSS treated with venous stent deployment were included. Patients in the control group were similar in age, gender, and absence of major comorbidities. VSI in the IVSS group was significantly higher at baseline compared with the control group (1.42 vs 0.97, p=0.01). Area under the ROC was 0.82. After stent deployment, VSI decreased significantly compared with baseline (1.04 vs 1.42, p<0.01).
Conclusion:
2D parametric parenchymal blood flow software is a useful tool which can accurately evaluate significant hemodynamic venous stenosis without intracranial catheterization, added radiation exposure, additional contrast injection, and periprocedural risks.
More Related Videos
09:36A Magnetic Resonance Imaging-based Computational Protocol for Analysis of Plaque Morphology and Hemodynamics in Patients with Carotid Artery Stenosis
Published on: August 12, 2025
04:01Point of Care Transcranial Color-Coded Duplex Ultrasound of the Middle Cerebral Artery
Published on: August 9, 2024