Related Experiment Video
Updated: Jan 3, 2026

07:41
Insertion, Maintenance, and Removal of the Percutaneous Dual Lumen Cannula Right Ventricular Assist Device
Published on: July 20, 2022
2.2K
First clinical experience with the double cuff tipless inflow cannula in the EVAHEART left ventricular assist system:
Ai Kawamura1, Koichi Toda1, Yoshiki Sawa1
1Department of Cardiovascular Surgery, Osaka University Graduate School of Medicine, Suita, Japan.
Artificial Organs
|November 28, 2019
Abstract
No abstract available in PubMed .
Related Concept Videos
Cardiac Catheterization II: Right Heart Catheterization
665
Right Heart Catheterization: An OverviewRight heart catheterization is an invasive diagnostic procedure that measures right-sided cardiac and pulmonary artery pressures, calculates cardiac output, and identifies intracardiac shunts. It provides detailed hemodynamic data essential for diagnosing and managing various cardiovascular conditions, such as pulmonary hypertension.Access SitesCommon access sites for right heart catheterization include the internal jugular vein in the neck region, the...
665
Cardiac Catheterization III: Left Heart Catheterization
504
Left heart catheterization is an invasive diagnostic procedure used to evaluate the function and structure of the left side of the heart. It is generally performed to diagnose and treat cardiovascular conditions such as valve abnormalities, coronary artery disease, and congenital heart defects.Diagnostic and therapeutic purposesLeft heart catheterization serves various diagnostic and therapeutic purposes, including:Assessing coronary artery bypass grafts.Evaluating coronary artery disease in...
504
Cardiac Catheterization IV: Nursing Management
573
Nursing responsibilities before cardiac catheterization include:Assess for allergies and establish baseline health status.Before cardiac catheterization, assess the patient for allergies to contrast dye. Perform a comprehensive baseline assessment, including vital signs, heart and breath sounds, and a neurovascular assessment of the extremities, noting distal pulses, skin color, and temperature. Instruct the patient to fast for 8-12 hours before the procedure. Evaluate baseline laboratory...
573
Hemodialysis II: Procedure and Complications
512
DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
512

