A Novel Method for Identifying Crack and Shaft Misalignment Faults in Rotor Systems under Noisy Environments Based on

Wang Zhao1, Chunrong Hua1, Dawei Dong1

  • 1School of Mechanical Engineering, Southwest Jiaotong University, Chengdu 610031, China.

Related Concept Videos

Stresses in a Shaft01:18

Stresses in a Shaft

The shaft PQ is subjected to a twisting force when equal and opposite torques are applied on either side. A section that cuts perpendicular to the shaft's axis at any arbitrary point R is examined to understand this. When the free-body diagram of the QR segment is analyzed, it reveals the shearing forces exerted by the PR portion onto the QR segment as the shaft experiences twisting.
Applying equilibrium conditions to the QR segment establishes that the internal shearing forces within the...
778
Residual Stresses in Circular Shafts01:10

Residual Stresses in Circular Shafts

In materials that exhibit elastic and plastic behavior, known as elastoplastic materials, residual stresses can accumulate when these materials experience plastic deformation. This deformation arises from either high levels of shearing stress or significant strains. Residual stresses are internal stresses that persist within a material after removing the external force causing deformation. This phenomenon is demonstrated when observing the behavior of a shaft under torque; notably, the...
470
Microcracking in Concrete01:20

Microcracking in Concrete

Microcracking in concrete refers to the tiny cracks that can form within the material even before any external load is applied. These microcracks typically occur at the interface between the coarse aggregate and the hydrated cement paste, often as a result of differential volume changes prompted by variations in stress-strain behavior, as well as thermal and moisture movement. Initially, these microcracks remain stable and do not grow substantially until the concrete is stressed to about 30...
390
Sequence Networks of Rotating Machines01:24

Sequence Networks of Rotating Machines

A Y-connected synchronous generator, grounded through a neutral impedance, is designed to produce balanced internal phase voltages with only positive-sequence components. The generator's sequence networks include a source voltage that is exclusively in the positive-sequence network. The sequence components of line-to-ground voltages at the generator terminals illustrate this configuration.
Zero-sequence current induces a voltage drop across the generator's neutral impedance and other...
452