Related Experiment Video
Updated: Jan 2, 2026

Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
Published on: July 29, 2013
Lesion measurement on a combined "all-in-one" window for chest CT: effect on intra- and interobserver variability
Annemiek Snoeckx1, Jeroen Cant2, Caro Franck3
1Department of Radiology, Antwerp University Hospital and University of Antwerp, Wilrijkstraat 10, 2650, Edegem, Belgium. annemiek.snoeckx@uza.be.
Purpose:
A newly developed image processing technique fuses conventional windows into a single 'All-In-One' (AIO) window. This study aims to evaluate variability of CT measurement of lesions in thoracic oncology patients on this novel AIO-window.
Methods:
Six radiologists with different levels of expertise measured 368 lesions of various size, origin and sharpness. All lesions were measured twice on the AIO-window and twice on the conventional window settings. Intraclass correlation coefficients and Bland-Altman plots were used to assess intra- and interobserver variability.
Results:
Overall intra-observer agreement for lesion diameters on the AIO-window and conventional window settings was 0.986 (95% Confidence interval (CI): 0.983-0.989) and 0.991 (95% CI 0.989-0.993) respectively. For interobserver agreement this was 0.982 (95% CI 0.979-0.985) (AIO) and 0.979 (95% CI 0.957-0.982) (conventional). For both the AIO and conventional windows, intra- and interobserver agreement were dependent on size, sharpness and reader experience. Measurement variability decreased with increasing lesion size. Regarding sharpness, inter- and intra-observer agreement ranged from 0.986-0.989 (AIO) and 0.985-0.992 (conventional) for well-defined lesions and from 0.978-0.983 (AIO) and 0.974-0.991 (conventional) for ill-defined lesions.
Conclusions:
Lesion diameters were consistently smaller on the AIO-window compared to conventional window settings. Overall intra- and interobserver variability rates were similar for the AIO-window and conventional window settings. We conclude that the AIO-window offers a reliable and reproducible alternative for measurement of thoracic lesions.
More Related Videos
08:39Longitudinal Micro-Computed Tomography Image Analysis for User-Defined Region of Interest in Critical-Sized Bone Defects
Published on: June 24, 2025
02:09Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
Published on: April 12, 2024
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System V: CT