Demonstration of a memory calibration method in water isotope measurement by laser spectroscopy
Dongmei Qu1, Lide Tian1,2,3, Huabiao Zhao1,3
1Key Laboratory of Tibetan Environment Changes and Land Surface Processes, Institute of Tibetan Plateau Research, Chinese Academy of Sciences, CAS, Beijing, 100101, China.
Rationale:
Measuring δ18 O and δ2 H values in water using wavelength-scanned cavity ring down spectroscopy (WS-CRDS) requires multiple injections of up to six (and sometimes eight or more) of one sample to remove the memory effect, which decreases the sample throughput and increases the consumables cost. Thus, improved methods for removing the memory effect are required.
Methods:
We calculated the memory coefficients by sequential WS-CRDS measurement of two lab standard waters with isotopic differences, and used them to establish calibration equations. We then used these equations to correct the measured δ18 O and δ2 H values by removing the memory effect, instead of using multiple injections in the routine daily measurements.
Results:
By using this method, the number of injections per sample was reduced to one. The reproducibility (one standard deviation) of the δ18 O and δ2 H values obtained for quality control sample was less than 0.05‰ and 0.5‰ for an annual average, respectively.
Conclusions:
By measuring the memory coefficients and establishing the calibration equations, a highly effective method was developed for determining the δ18 O and δ2 H values of water, which could significantly improve sample throughput for liquid water dual isotope measurement without sacrificing the precision.
More Related Videos
09:40Measurement and Analysis of Atomic Hydrogen and Diatomic Molecular AlO, C2, CN, and TiO Spectra Following Laser-induced Optical Breakdown
Published on: February 14, 2014
08:53Dependence of Laser-induced Breakdown Spectroscopy Results on Pulse Energies and Timing Parameters Using Soil Simulants
Published on: September 23, 2013
Related Concept Videos
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...