Multiplex analysis of antigen-specific memory B cells in humans using reversed B-cell FluoroSpot
Peter Jahnmatz1, Christopher Sundling2, Bartek Makower3
1Division of Infectious Diseases, Department of Medicine Solna, Karolinska Institutet, Stockholm, Sweden; Mabtech AB, Nacka Strand, Sweden.
Abstract:
Analysis of B-cell specificities at the single cell level provides important information on how the B-cell compartment responds when challenged by infection or vaccination. We recently developed a reversed B-cell FluoroSpot assay and showed that it could be used to detect B cells specific for different antigens simultaneously in a mouse model. The aim of this study was to further develop the method to detect and quantify antigen-specific memory B cells (MBCs) in humans where circulating antigen-specific cells are less frequent. We show that MBCs specific for three antigens, tetanus toxoid, hepatitis B surface antigen and cytomegalovirus pp65, could be detected simultaneously in one well. In addition to enumerating antigen-specific MBCs, we also assessed the spot volume to estimate the intensity of the response in individual cells and found this to be a new and sensitive approach to study MBC responses after vaccination. This unique B-cell FluoroSpot approach provides a simple and sensitive multiplex analysis of MBCs and can be adapted to most antigens and host species.