Related Experiment Video
Updated: Jan 2, 2026

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Random Forests machine learning applied to gas chromatography - Mass spectrometry derived average mass spectrum data
Leo Lebanov1, Laura Tedone2, Alireza Ghiasvand3
1Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, 7001, Australia; ARC Industrial Transformation Research Hub for Processing Advanced Lignocellulosics (PALS), School of Natural Sciences, University of Tasmania, Hobart, Tasmania, 7001, Australia.
Abstract:
Differences in chemical profiles of various essential oils (EOs) come from the fact that each plant species and chemotype has a distinctive secondary metabolism. Therefore, these differences can be used as the chemical markers for EO classification and determination of their quality. Herein, the Random Forests (RF) machine learning algorithm was applied to the classification of 20 different EOs. From three-way raw gas chromatography - mass spectra data, total chromatogram average mass spectra (TCAMS) and segment average mass spectra (SAMS) were created. TCAMS was generated by averaging response of each m/z over the whole chromatogram and SAMS by averaging the response of each fragment across a certain time segment within the chromatogram. The RF model was applied to the two data sets and optimised through the evaluation of pre-processed data, number of trees, and number of variables used in each node split. The performance of the model was evaluated through a cross-validation process, repeated 50 times by dividing the whole sample set into training and validation subsets. The calculated average out-of-bag error (OOBE), over 50 different training TCAMS data sets was 3.22 ± 1.29%, while for SAMS it was found to be 2.28 ± 1.33%. The minimal number of variables necessary for EO classification was determined by a nested cross-validation process. The amount of reduced variables in each step was 10%. It was shown that the TCAMS data set with 6 variables had similar prediction power as the SAMS with 30 variables. OOBE for classification of 20 EOs was 2.89 ± 1.44% and 3.70 ± 1.73%, for TCAMS and SAMS, respectively. Proximity between samples was used to evaluate their qualities. Samples with greater intra-class proximity had good similarity, while the lower ones indicated greater variations in the chemical profiles. The SAMS data set showed superior potential for quality assurance, compared with TCAMS.
More Related Videos
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Aromatic Compound Fragmentation
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Mass Spectrometry: Branched Alkane Fragmentation
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...