Independent components analysis (ICA) at the "cocktail-party" in analytical chemistry
Yulia B Monakhova1, Douglas N Rutledge2
1Spectral Service AG, Emil-Hoffmann-Straße 33, 50996, Cologne, Germany; Institute of Chemistry, Saratov State University, Astrakhanskaya Street 83, 410012, Saratov, Russia; Institute of Chemistry, Saint Petersburg State University, 13B Universitetskaya Emb., St Petersburg, 199034, Russia.
Abstract:
Independent components analysis (ICA) is a probabilistic method, whose goal is to extract underlying component signals, that are maximally independent and non-Gaussian, from mixed observed signals. Since the data acquired in many applications in analytical chemistry are mixtures of component signals, such a method is of great interest. In this article recent ICA applications for quantitative and qualitative analysis in analytical chemistry are reviewed. The following experimental techniques are covered: fluorescence, UV-VIS, NMR, vibrational spectroscopies as well as chromatographic profiles. Furthermore, we reviewed ICA as a preprocessing tool as well as existing hybrid ICA-based multivariate approaches. Finally, further research directions are proposed. Our review shows that ICA is starting to play an important role in analytical chemistry, and this will definitely increase in the future.
More Related Videos
08:12Author Spotlight: Exploring Light-Driven Chemical Reactions and Energy-Harnessing Devices in Photochemical Research
Published on: February 16, 2024
10:13Using Capillary Electrophoresis to Quantify Organic Acids from Plant Tissue: A Test Case Examining Coffea arabica Seeds
Published on: November 12, 2016
Related Concept Videos
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Qualitative Analysis
There are two main approaches to qualitative analysis:...
¹H NMR Signal Integration: Overview
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....