Related Experiment Video
Updated: Jan 2, 2026

A Novel Digital Platform for a Monitored Home-based Cardiac Rehabilitation Program
Published on: April 19, 2019
NFC-Powered Flexible Chest Patch for Fast Assessment of Cardiac, Hemodynamic, and Endocrine Parameters
Abstract:
Cardiac-related diseases are still the number one cause of death worldwide. Methods and technologies to suppress this problem are currently being investigated by integrating electrocardiographic (ECG) monitoring with other sensing modalities in order to detect these diseases more accurately and in due course of time. In this paper, we propose a battery-less and flexible device to be worn as a chest patch for monitoring cardiac and hemodynamic parameters through electrical and acoustic measurements, combined with sweat pH level estimation and skin temperature, by swiping a smartphone over the patch area for enough time (≃5 seconds) to allow adequate acquisition and estimation of the aforementioned parameters. Fast screening of vital signals from patients in ambulatory or emergency scenarios can thus be achieved by this Near Field Communication (NFC) powered device, as well as home or office monitoring for those individuals suffering from diseases affecting the hemodynamic, cardiac and endocrine parameters detected by the proposed technology. Current consumption of the device is 1 mA for harvested levels of 1.8 V, yielding a power requirement of 1.8 mW. Within these conditions, the sensitivities achieved by each sensing modality are 42 mV/unit for pH, 0.12 °C for temperature, 48 dB SNR for ECG and -56 dBA for acoustic measurements.
More Related Videos
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
04:20Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
Related Concept Videos
Holter Monitor: 24-Hour Monitoring
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Electrocardiogram