Related Experiment Video
Updated: Jan 2, 2026

Dry Powder and Nebulized Aerosol Inhalation of Pharmaceuticals Delivered to Mice Using a Nose-only Exposure System
Published on: April 6, 2017
Dry Powder and Budesonide Inhalation Suspension Deposition Rates in Asthmatic Airway-Obstruction Regions
Norihide Murayama1, Kei Asai2, Kikuno Murayama1
1Department of Pediatrics, Murayama Pediatrics, 3-2-33 Nagayoshi-Nagahara-Higashi Hirano-ku Osaka-shi, 547-0013 Osaka, Japan.
Optimal budesonide inhalation therapy for asthma involves specific particle sizes. Electric nebulizers, particularly the NE-C28, deliver significantly more medication to the airway obstruction region compared to dry powder inhalers.
Area of Science:
- Respiratory Medicine
- Pharmacology
- Biomedical Engineering
Background:
- Inhaled corticosteroids are standard therapy for bronchial asthma.
- Current inhalation devices produce a wide range of particle sizes.
- Effective drug delivery to the airway obstruction region is crucial for asthma management.
Purpose of the Study:
- To compare the deposition rates of different budesonide formulations and devices in the airway obstruction region.
- To identify inhalation therapies that maximize drug delivery to the tracheobronchial area.
- To determine the optimal particle size for budesonide deposition in asthma.
Main Methods:
- Utilized Weibel's anatomical data to define the airway obstruction region (1st-4th bronchial generations).
- Analyzed budesonide particle size distribution and average diameter for various delivery systems.
- Measured drug deposition using High-Performance Liquid Chromatography (HPLC) with a Cascade Impactor.
Main Results:
- Particles sized 2-6 µm are optimally deposited in the identified airway obstruction region.
- Jet-type NE-C28 suspension (78.0%) and mesh-type NE-U22 suspension (59.0%) showed higher proportions of optimal particle sizes compared to dry powder inhalers (Turbuhaler 33.0%, Symbicort 32.0%).
- The NE-C28 nebulizer delivered 2.36 times more budesonide to the target region than dry powder systems.
Conclusions:
- Electric nebulizers are more effective than dry powder inhalers for budesonide delivery in asthma.
- The jet-type NE-C28 suspension demonstrates superior efficacy in delivering budesonide to the airway obstruction region.
- Optimizing particle size is key to enhancing inhaled corticosteroid therapy for bronchial asthma.
Related Concept Videos
Inhaled Medications
Antiasthma Drugs: β2-Adrenoceptor Agonists
One class of bronchodilators includes β2-adrenoceptor agonists. These agents target the β2-adrenoceptors located on bronchial smooth muscle cells. By stimulating these receptors, β2-agonists induce...
Antiasthma Drugs: Inhaled Corticosteroids and Glucocorticoids
ICS work through a multifaceted mechanism of action. They suppress the inflammatory response caused by the proliferation of TH cells. They also reduce the transcription of the IL-2 gene, which is involved in the...
Asthma-IV: Diagnostic and Management
Clinical Assessment for Asthma:
This is the first step in diagnosing and managing asthma. It includes:
Drugs Used in Lower Respiratory Disorders: Overview
Bronchodilators, the first step of respiration enhancement, come in various forms, each with its own mechanism...
Additional Routes of Drug Administration
Administering drugs via inhalation allows for the direct delivery of gaseous, volatile substances or droplets to different parts of the respiratory tract. One of the advantages of the inhalation route is the rapid absorption of drugs into the circulatory system, which is possible because of the large surface area of...