A Structured Rehabilitation Protocol for Improved Multifunctional Prosthetic Control: A Case Study
Published on: November 6, 2015
Closed-Loop Multi-Amplitude Control for Robust and Dexterous Performance of Myoelectric Prosthesis
Abstract:
In the case of a hand amputation, the affected person can use a myoelectric prosthesis to substitute the missing limb and regain motor functions. Unfortunately, commercial methods for myoelectric control, although robust and simple, are unintuitive and cognitively taxing when applied to an advanced multi-functional prosthesis. The state-of-the-art methods developed in academia are based on machine learning and therefore require long training and suffer from a lack of robustness. This work presents a novel closed-loop multi-level amplitude controller (CMAC), which aims at overcoming these drawbacks. The CMAC implements three degrees-of-freedom (DoF) control by thresholding the muscle contraction intensity during wrist flexion and extension movements. Unique features of the controller are the vibrotactile feedback that communicates the state of the controller to the user and a scheme for proportional control. These components allow exploiting the full dexterity of the prosthesis using a simple two-channel myoelectric interface. The CMAC was compared to a commonly implemented pattern-recognition method (linear discriminant analysis - LDA) using clinically relevant tests in 12 able-bodied and 2 amputee subjects. The experimental assessment demonstrated that CMAC was similarly fast as LDA in dexterous tests (clothespin and cube manipulation), while it was somewhat slower than LDA during a simple, single DoF task (box and blocks). In addition, in all the tasks, LDA and CMAC resulted in a similarly low error rate. On the other hand, to an amputee that could not generate six distinguishable classes using LDA, the CMAC still enabled the control of all the prosthesis DoFs. Importantly, the overall setup and training time in CMAC were significantly lower compared to LDA. In conclusion, the novel method is convenient for clinical applications, and allows substantially higher control dexterity compared to what can be normally achieved using conventional two channel EMG. Therefore, CMAC provides performance comparable to advanced machine-learning algorithms and the robustness and ease of use that is characteristic for the simple two-channel myoelectric interface.
More Related Videos
09:14Surface Electromyographic Biofeedback as a Rehabilitation Tool for Patients with Global Brachial Plexus Injury Receiving Bionic Reconstruction
Published on: September 28, 2019
07:59Therapy Interventions for Upper Limb Amputees Undergoing Selective Nerve Transfers
Published on: October 29, 2021
Related Concept Videos
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
Feedback control systems
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Motor Unit Stimulation
The latent period of contraction marks the onset of excitation-contraction coupling, when the action potential propagates across the sarcolemma, preparing the muscle fibers for contraction. As the fibers enter the contraction phase, the...
PD Controller: Design
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...