F-18 FDG PET brain imaging in symptomatic arthroprosthetic cobaltism
Robert L Bridges1, Christina S Cho2,3, Marc R Beck2,4
1Aegis Imaging Consultants, LLC, P.O. Box 751, 170 Cervin Circle, Girdwood, AK, 99587, USA. rbridgesmd@hotmail.com.
Purpose:
Imaging studies of cobalt toxicity from cobalt-chromium alloy arthroprosthetics have focused on the local intra-articular and peri-articular presentation from failing joint replacements. Most studies investigating neurological findings have been small case series focused on the clinical findings of memory loss, diminished executive function, tremor, hearing and vision loss, depression, and emotional lability. This study utilizes software-based quantitative analysis of brain metabolism to assess the degree of hypometabolism and areas of susceptibility, determine if a pattern of involvement exists, and measure reversibility of findings after prosthetic revision to cobalt-free appliances.
Methods:
Over 48 months, 247 consecutive patients presenting to an orthopedic clinic with an arthroprosthetic joint containing any cobalt-chromium part were screened with whole blood and urine cobalt levels. A clinically validated inventory of 10 symptoms was obtained. Symptomatic patients with a blood cobalt level above 0.4 mcg/L or urine cobalt greater than 1 mcg/L underwent F-18 FDG PET brain imaging. Analysis was performed with FDA-approved quantitative brain analysis software with the pons as the reference region. Control group was the normal brain atlas within the software.
Results:
Of the 247 consecutively screened patients, 123 had blood and urine cobalt levels above the threshold. The 69 scanned patients had statistically significant regional hypometabolism and higher symptoms inventory. Fifty-seven patients were retained in the study. Distribution of hypometabolism was in descending order: temporal, frontal, Broca's areas, anterior cingulate, parietal, posterior cingulate, visual, sensorimotor, thalamic, and lastly caudate. Metal-on-metal (MoM) and metal-on-plastic (MoP) joint replacements produced similar patterns of hypometabolism. Of 15 patients with necessary revision surgery, 8 demonstrated improved metabolism when later re-scanned.
Conclusion:
All scanned patients had regions of significant hypometabolism. Neurological toxicity from elevated systemic cobalt levels following arthroprosthetic joint replacement has a pattern of regional susceptibility similar to heavy metals and solvents, differing from classical dementias and may occur at blood and urine cobalt levels as low as 0.4 mcg/L and 1 mcg/L, respectively. Presently accepted thresholds for cobalt exposure and monitoring may need revision. Quantitative F-18 FDG PET brain imaging may aid in the decision process for treatment options and timing of possible medical versus surgical intervention.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET

![Quantitative [18F]-Naf-PET-MRI Analysis for the Evaluation of Dynamic Bone Turnover in a Patient with Facetogenic Low Back Pain](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F58491.jpg&w=3840&q=50)