Related Experiment Video
Updated: Jan 1, 2026

An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
Published on: November 13, 2016
Biomechanical Analysis of a Novel Syndesmotic Plate Compared With Traditional Screw and Suture Button Fixation
Qihao Weng1, Chuanlu Lin1, Yang Liu1
1Foot and Ankle Surgeon, Department of Orthopaedics, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou, China; Master's Student, The Second School of Medicine, Wenzhou Medical University, Wenzhou, China.
Abstract:
Many lateral malleolus fractures have been found to have syndesmosis injuries after anatomic reduction. The main methods for the treatment of syndesmosis injuries are screw fixation and suture-button flexible fixations. In pursuit of innovation, we have designed a novel syndesmotic plate (NSP) for simultaneous fixation of lateral malleolus fractures and distal tibiofibular syndesmosis injuries. The purpose of this study is to compare the biomechanical characteristics of the NSP to syndesmotic screw and suture-button fixations. Twelve adult cadaveric specimens were used in this experiment. Axial loading as well as rotation torque were applied in 3 different ankle positions: neutral, dorsiflexion, and plantarflexion. After the initial specimens were tested, they were made into a pronation-abduction III fracture model as described by Lauge-Hansen. Subsequently, the specimens were fixed sequentially using a distal fibular anatomic locking plate (DFALP) combined with syndesmotic screws, DFALP combined with suture button, and NSP. Then the above tests were repeated. The syndesmotic displacement and the strain of the tibia and fibula were recorded during the experiment. In most cases, the displacements and strains of the NSP group and the screw group were smaller than the suture button groups and the native (SBGAN) (p < .05), and the displacements and strains of the NSP group were also slightly smaller than the screw group in most cases, and there was no significant difference between the 2 groups. The NSP we developed has a fixed strength no less than the traditional syndesmotic screw fixation. This provides us a new idea for the treatment of distal tibiofibular syndesmosis injuries.
More Related Videos
06:41A Minimally Invasive Model to Analyze Endochondral Fracture Healing in Mice Under Standardized Biomechanical Conditions
Published on: March 22, 2018
05:34A Mini-Invasive Internal Fixation Technique for Studying Immobilization-Induced Knee Flexion Contracture in Rats
Published on: May 20, 2019