A new injection rate estimation technique for on-site screening test of medication infusion pump by nurses
Gun Ho Kim1, Sung Uk Yun2, Jung Hoon Ro3
1Interdisciplinary Program in Biomedical Engineering, School of Medicine, Pusan National University, Yangsan, Korea.
Abstract:
Medication infusion pumps are the most popular device in almost all areas of a hospital; therefore, it is important to frequently inspect the accuracy of the infusion pump operation to prevent underdose/overdose accidents. However, the conventional infusion pump inspection devices are not suitable for quick and convenient on-site inspection by nurses. In this study, a new IR estimation technique for peristaltic infusion pumps that facilitates on-site pre-screening test with shorter inspection time was proposed. A thin membrane potentiometer was attached to a catheter and the actual IR was estimated based on a time interval between two successive line pushes of an identical cam follower using power function estimation. To evaluate the performance of the proposed IR estimation technique, in vitro experiments were performed using 11 infusion pumps (three for Infusion Pump SET 1 (IPSET-1) and eight for Infusion Pump SET 2 (IPSET-2)) with the same model. In experiments, error rate between the actual and the measured values (using conventional inspection device) were 0.04-1.17% range for IPSET-1 and 2.09-4.32% for IPSET-2, and those between the actual and the estimated values (using proposed method) were 0.02-0.62% range for IPSET-1 and 1.31-4.23% for IPSET-2. The proposed technique had almost equivalent performance with a commercial inspection device, but the time for inspection was reduced to almost one third. We expect that the proposed technique can provide a tool for simple and convenient on-site pre-screening of infusion pumps by nurses to improve patient safety.
Related Concept Videos
One-Compartment Model: IV Infusion
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...
Drug Accumulation During Multiple Dosing: Intermittent IV Infusions
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Drug Accumulation During Multiple Dosing: Repetitive IV Injections
Two-Compartment Open Model: IV Infusion
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...
Estimation of k and VD of Aminoglycosides