Maximum likelihood activity and attenuation estimation using both emission and transmission data with application to
Li Cheng1,2, Tianyu Ma2, Xuezhu Zhang1
1Department of Biomedical Engineering, University of California-Davis, Davis, CA, 95616, USA.
Purpose:
We present a new method for joint reconstruction of activity and attenuation images using both emission and transmission data and demonstrate its advantage over the standard maximum likelihood activity and attenuation (MLAA) reconstruction using emission data alone.
Methods:
We define a joint likelihood function including both time-of-flight (TOF) emission data and transmission data. The latter can be obtained from an external source or from Lu-176 background radiation. Activity and attenuation images are estimated jointly by maximizing the likelihood function. The proposed method solves the undetermined scale problem in the conventional MLAA. A monotonically convergent algorithm was derived to optimize the objective function. Furthermore, we present a theoretical analysis of the noise propagation in the joint reconstruction. Simulations and phantom experiments were conducted to validate the feasibility of the proposed method.
Results:
Quantitatively correct and less noisy images were reconstructed with the proposed method. Artifacts in the attenuation map reconstructed from the standard MLAA were removed by incorporating transmission data. Noise analysis was validated with different transmission sources and transmission count levels. The theoretical prediction indicated that noise of activity map would not change in a large range of transmission count level and a very low transmission count level could result in good estimation.
Conclusions:
The results demonstrate the feasibility of obtaining quantitatively correct images in TOF PET by using both emission and (weak) transmission data. The noise analysis also provides guidance for choosing a proper transmission source configuration to reduce noise propagation.
More Related Videos
06:28Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
09:03Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Biological Effects of Radiation
Absorption of Radiation
Atomic Emission Spectroscopy: Interference
Radiation: Applications
The average...
Types of Radioactivity
Alpha (α) decay is the emission of an α particle from the nucleus. For example, polonium-210 undergoes α decay: