A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
Development of an automatic sequential injection analysis-lab on valve system exploiting molecularly imprinted
1Sciware Systems, S.L. Spin-off from the University of the Balearic Islands, C/ Pi 37, 07193, Illes Balears, Spain.
Abstract:
In recent years, the discharge of estrogens into the environmental water bodies through the effluents of sewage treatment plants is an issue of increasing concern, since they can act as endocrine-disrupting compounds. For this reason, there is a need of developing selective, sensitive and environmentally friendly methodologies for their determination. In this work, we present an automatic procedure for the clean-up, preconcentration and quantification of the estrogens most used in contraceptives (estrone, E1; 17β-estradiol, E2; estriol, E3; and 17α-ethynylestradiol, EE2), which are also catalogued as Contaminants of Emergent Concern by the Environmental Protection Agency of the United States (US EPA). A sequential injection analysis-lab on valve system (SIA-LOV) using a molecularly imprinted polymer (MIP) as a sorbent has been developed to perform the selective microsolid phase extraction (μSPE) of the analytes in a fully automated way. Several parameters affecting the extraction have been optimized following multivariate approaches. Besides, the preconcentration system has been coupled to an HPLC for the estrogens quantification. Low limits of detection (LODs) and limits of quantification (LOQs) have been achieved; hence the studied estrogens can be quantified in a wide range of concentrations, i.e. 9.2-100 μg L-1 of E3, 8.7-100 μg L-1 of E2, 6.5-100 μg L-1 of EE2 and 7.9-100 μg L-1 of E1. Besides, satisfactory precision has been obtained, with relative standard deviations (RSDs) lower than 4.9% and 12.1% for intra and inter-day precision, respectively. Finally, the method has been successfully applied to real wastewater samples.
More Related Videos
09:49Use of a Battery of Chemical and Ecotoxicological Methods for the Assessment of the Efficacy of Wastewater Treatment Processes to Remove Estrogenic Potency
Published on: September 11, 2016
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...