Related Experiment Video
Updated: Dec 31, 2025

Quantifying the Relative Thickness of Conductive Ferromagnetic Materials Using Detector Coil-Based Pulsed Eddy Current Sensors
Published on: January 16, 2020
Investigation of the eddy current effect on the high frequency response of the Mirnov probe on J-TEXT
Chengshuo Shen1, Zhenming Cai1, Tian Ren1
1International Joint Research Laboratory of Magnetic Confinement Fusion and Plasma Physics, State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, People's Republic of China.
Abstract:
This paper investigates the high frequency response of the Mirnov probe based on a test platform, which is capable of generating a uniform AC magnetic field within the frequency range of 1-300 kHz. The eddy current effect is quantitatively reflected by the phase shift ϕc and normalized amplitude δ of the measured magnetic field between cases with and without a conducting plate located near the Mirnov probe. This method compensates the resonant effect in the Mirnov probe circuit and hence reflects purely the eddy current effect. The eddy current effect increases with the decrease in the distance between the probe and the conducting plate. With the increase in frequency, the magnitude of δ decreases to a saturated value at 10 kHz but increases significantly above 100 kHz for 304-stainless steel, while the eddy current effect with graphite appears at around 10 kHz and the magnitude of δ decreases to the minimum at 125 kHz, followed by a significant increase above 125 kHz. With the increase in f, the magnitude of ϕc increased until 2.5 kHz and 40 kHz for steel and graphite, respectively, then decreased with a further increase in f. The phasor expression is introduced to describe the AC magnetic field and allows an easy expression of the eddy current field. The phase of the eddy current field decreases toward -180° with f. The amplitude of the eddy current field increases with f and reaches its maximum when the skin depth reduces to a critical value. The eddy current field decreases with a further increase in the frequency.
Related Concept Videos
Magnetic Field Due To A Thin Straight Wire
Magnetic Susceptibility and Permeability
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
Eddy Currents
Other major applications of eddy currents appear in metal detectors and the braking systems of trains and roller...
Magnetic Field Of A Current Loop
Magnetic Field Due to Two Straight Wires
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...