A partial-dithering strategy for edge-illumination x-ray phase-contrast tomography enabled by a joint reconstruction
Yujia Chen1, Charlotte K Hagen2, Alessandro Olivo2
1Department of Biomedical Engineering, Washington University in St Louis, Campus Box 1097, One Brookings Drive, St Louis, MO, 63130, United States of America.
Edge-illumination x-ray phase-contrast tomography (EIXPCT) can achieve high resolution using dithering. A new partial-dithering strategy reduces acquisition time while maintaining comparable spatial resolution to full dithering.
Area of Science:
- Medical Imaging
- X-ray Tomography
- Materials Science
Background:
- Edge-illumination x-ray phase-contrast tomography (EIXPCT) estimates refractive index distribution.
- Image resolution is limited by mask period but improved by dithering.
- Dithering increases data acquisition time and radiation dose.
Purpose of the Study:
- Propose a novel partial-dithering strategy for EIXPCT data acquisition.
- Reduce data acquisition time and radiation dose.
- Maintain high spatial resolution.
Main Methods:
- Implemented dithering at a subset of tomographic view angles.
- Utilized a joint reconstruction method for data analysis.
- Explored the effect of dithering parameters on image resolution.
Main Results:
- Partial dithering achieved spatial resolution comparable to full dithering.
- Acquisition time was substantially decreased compared to full dithering.
- The strategy offers a balance between resolution and efficiency.
Conclusions:
- Partial dithering is an effective strategy for EIXPCT.
- Reduces acquisition time and radiation dose without compromising resolution.
- Enables more flexible data-acquisition designs.
Related Concept Videos
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Imaging Studies III: Computed Tomography
X-ray Imaging