Related Experiment Video
Updated: May 3, 2026

07:32
Dynamic Electrochemical Measurement of Chloride Ions
Published on: February 5, 2016
10.5K
The spectrophotometric determination of nanomole quantities of chloride in plant tissue
Analytical Biochemistry
|August 15, 1988
Abstract:
The determination of Cl- in plant tissues was investigated by FeSCN2+ spectrophotometry following SCN- displacement from Hg(SCN)2 by Cl-. The calibration curve was nonlinear, but consistent and reproducible. As little as 10 nmol Cl- could be measured. There was no obvious interference in color development by water-soluble components in plant tissues. Values obtained by this method were in close agreement with those obtained potentiometrically and by coulometric titration.
Related Concept Videos
Precipitation Titration Curve: Analysis
2.1K
The precipitation titration curve demonstrates the change in concentration of one reactant with the volume of titrant added. During the titration of chloride ions with silver nitrate, the precipitation titration curve is divided into three regions: before, at, and after the equivalence point. Before the equivalence point, low redissolution of the sparingly soluble silver chloride precipitate gives a low silver ion concentration. However, in the second region, representing the equivalence point,...
2.1K
Precipitation Titration: Endpoint Detection Methods
5.1K
In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...
In the Volhard method, a standard excess of AgNO3 is first added to the...
5.1K
Flame Photometry: Lab
1.3K
In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
1.3K
Transport Number
230
The transport number is the fraction of the total current carried by an ion in an electrolyte solution. It is defined as the ratio of the current carried by a specific ion to the total current flowing through the solution. The transport number, t, is central to understanding ionic mobility, which describes how fast an ion moves under the influence of an electric field. This link connects the physical behavior of ions in solution to the chemical processes that occur during electrochemical...
230

