Development of two-dimensional gas chromatography (GC×GC) coupled with Orbitrap-technology-based mass spectrometry:
Nguyen Viet Hung1, Chetna Mohabeer2, Marie Vaccaro1
1Laboratoire SMS-EA3233, UNIROUEN, Normandie Université, Place Emile Blondel, F-76821, Mont-Saint-Aignan Cedex, France.
Abstract:
Comprehensive gas chromatography (GC) has emerged in recent years as the technique of choice for the analysis of volatile and semivolatile compounds in complex matrices. Coupling it with high-resolution mass spectrometry (MS) makes a powerful tool for identification and quantification of organic compounds. The results obtained in this study showed a significant improvement by using GC×GC-EI-MS in comparison with GC-EI-MS; the separation of chromatogram peaks was highly improved, which facilitated detection and identification. However, the limitation of Orbitrap mass analyzer compared with time-of-flight analyzer is the data acquisition rate; the frequency average was about 25 Hz at a mass resolving power of 15.000, which is barely sufficient for the proper reconstruction of the narrowest chromatographic peaks. On the other hand, the different spectra obtained in this study showed an average mass accuracy of about 1 ppm. Within this average mass accuracy, some reasonable elemental compositions can be proposed and combined with characteristic fragment ions, and the molecules can be identified with precision. At a mass resolving power of 7.500, the scan rate reaches 43 Hz and the GC×GC-MS peaks can be represented by more than 10 data points, which should be sufficient for quantification. The GC×GC-MS was also applied to analyze a cellulose bio-oil sample. Following this, a highly resolved chromatogram was obtained, allowing EI mass spectra containing molecular and fragment ions of many distinct molecules present in the sample to be identified.
More Related Videos
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
MALDI-TOF Mass Spectrometry