Related Experiment Video
Updated: Dec 31, 2025

Calvarial Model of Bone Augmentation in Rabbit for Assessment of Bone Growth and Neovascularization in Bone Substitution Materials
Published on: August 13, 2019
Effects of Ultraviolet Photoactivation on Osseointegration of Commercial Pure Titanium Dental Implant After 8 Weeks
Arturo Sanchez-Perez1, Carlos Cachazo-Jiménez2, Carmen Sánchez-Matás3
1Periodontics Unit, Medicine and Dentistry, University of Murcia, Spain.
Abstract:
This study investigated whether a 6-Watt ultraviolet C-lamp was capable of producing photofunctionalization on commercial implants during a medium observation term of 8 weeks. A total of 20 implants were inserted in 5 New Zealand rabbits, with each animal receiving 2 implants per tibia (one photofunctionalized and one untreated), according to a previously established randomization sequence. All implants were inserted by a single surgeon following the manufacturer's instructions. Histological analysis was performed by an evaluator who was blinded to the treatment condition. After 8 weeks of healing, the 2 groups showed no statistically significant differences in terms of bone-to-implant contact. Compared to control implants, the photofunctionalized implants showed improved wettability and more homogenous results. Within the limits of the present study, the use of this 6-W ultraviolet C-lamp, for an irradiation time of 15 minutes at a distance of 15 cm, did not improve the percentages of bone-to-implant contact in rabbits at an osseointegration time of 8 weeks.