Effects of scout radiographic imaging conditions on tube current modulation in chest computed tomography
1Department of Diagnostic Radiology, Kitasato University School of Medicine, Sagamihara, Japan.
Abstract:
For the optimisation of radiation dose in computed tomography (CT), dose reduction is attempted while preserving diagnostic performance. To reduce the overall radiation dose related to CT, the dose from scout radiography may be reduced by decreasing the tube voltage and tube current. We evaluated the effects of scout imaging conditions on CT radiation dose. An anthropomorphic chest phantom was imaged on two CT scanners (scanners A and B) from different vendors, manipulating the scout imaging conditions in terms of imaging direction, tube voltage and tube current, and assessed the tube current modulation in subsequent CT and pixel values in scout radiographs. The direction of the scout radiography influenced the shape of the tube current modulation curve and total radiation dose in subsequent CT. When compared with the use of the lateral projection, use of the posteroanterior or anteroposterior projection alone increased the radiation dose substantially on scanner A, but did not change, or mildly decreased, the dose on scanner B. When imaged using the lateral scout on scanner A, reduction in tube voltage and tube current for scout radiography decreased the CT dose in the cranial part of the scan range and, to a lesser degree, the total radiation dose. On the low-voltage, low-current lateral radiograph, the image contrast was impaired and pixel values were underestimated around the lung apex. Without the use of the lateral radiograph, neither the tube voltage nor tube current for scout radiography influenced the CT dose. On scanner B, reduced tube voltage for scout radiography increased the CT dose. In conclusion, reduced tube voltage and tube current may affect scout radiographs, resulting in alteration of the tube current modulation pattern and total radiation dose in subsequent CT. These effects vary depending on the CT scanners and scout direction.
More Related Videos
08:30X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...