Application of electron channeling contrast imaging to 3D semiconductor structures through proper detector

Han Han1, Thomas Hantschel2, Libor Strakos3

  • 1imec, Kapeldreef 75, Leuven 3001, Belgium; KU Leuven, Dept. of Physics and Astronomy, Celestijnenlaan 200D, Leuven 3001, Belgium.

Ultramicroscopy
|January 10, 2020
PubMed

Related Concept Videos

Scanning Electron Microscopy01:07

Scanning Electron Microscopy

A scanning electron microscope (SEM) is used to study the surface features of a sample by using an electron beam that scans the sample surface in a two-dimensional manner. Typically, areas between ~1 centimeter to 5 micrometers in width can be imaged. SEM can be used to image bacteria, viruses, tissues as well as larger samples like insects. Conventional SEM gives a magnification ranging from 20X to 30,000X and spatial resolution of 50 to 100 nanometers.
Fundamental Principles
Accelerated...
5.2K
Three-Dimensional Microscopy in Microbiology01:28

Three-Dimensional Microscopy in Microbiology

Three-dimensional imaging techniques are essential in cell biology, allowing researchers to visualize intricate cellular structures with high resolution. Two prominent methods, Differential Interference Contrast Microscopy (DIC) and Confocal Scanning Laser Microscopy (CSLM), provide distinct advantages for imaging live and thick specimens, respectively.Differential Interference Contrast MicroscopyDIC microscopy enhances contrast in transparent, unstained samples by converting phase...
709
Electron Microscope Tomography and Single-particle Reconstruction01:07

Electron Microscope Tomography and Single-particle Reconstruction

Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
2.8K
Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
11.9K