Related Experiment Video
Updated: Dec 31, 2025

Electron Channeling Contrast Imaging for Rapid III-V Heteroepitaxial Characterization
Published on: July 17, 2015
Application of electron channeling contrast imaging to 3D semiconductor structures through proper detector
Han Han1, Thomas Hantschel2, Libor Strakos3
1imec, Kapeldreef 75, Leuven 3001, Belgium; KU Leuven, Dept. of Physics and Astronomy, Celestijnenlaan 200D, Leuven 3001, Belgium.
Abstract:
Nowadays electron channeling contrast imaging (ECCI) is widely used to characterize crystalline defects on blanket semiconductors. Its further application in the semiconductor industry is however challenged by the emerging rise of nanoscale 3D heterostructures. In this study, an angular multi-segment detector is utilized in backscatter geometry to investigate the application of ECCI to the defect analysis of 3D semiconductor structures such as III/V nano-ridges. We show that a low beam energy of 5 keV is more favorable and that the dimension of 3D structures characterized by ECCI can be scaled down to ~ 28 nm. Furthermore, the impact of device edges on the collected ECCI image is investigated and correlated with tool parameters and cross-section profiles of the 3D structures. It is found that backscattered electrons (BSE) emitted from the device edge sidewalls and generating the bright edges (edge effects), share a similar angular distribution to those emitted from the surface. We show that the collection of low angle BSEs can suppressed the edge effects, however, at the cost of losing the defect contrast. A positive stage bias suppresses edge effects by removing the inelastically backscattered electrons from the sidewalls, but low loss BSEs from the sidewalls still contribute to the ECCI micrographs. On the other hand, if segments of an angular backscatter (ABS) detector are properly aligned with the nano-ridges, BSEs emitted from the sidewall and the surface can be separated, thus leading to the completely absence of one bright edge on the surface without compromise of the defect contrast. The merging of two such ECCI images reveals the nano-ridge surface without edge effects.
More Related Videos
11:14Comprehensive Characterization of Extended Defects in Semiconductor Materials by a Scanning Electron Microscope
Published on: May 28, 2016
07:24Quantitative Atomic-Site Analysis of Functional Dopants/Point Defects in Crystalline Materials by Electron-Channeling-Enhanced Microanalysis
Published on: May 10, 2021
Related Concept Videos
Scanning Electron Microscopy
Fundamental Principles
Accelerated...
Three-Dimensional Microscopy in Microbiology
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...