Related Experiment Video
Updated: Dec 31, 2025

An In Vitro Bladder Model of Catheter-Associated Urinary Tract Infection
Published on: June 24, 2025
Reducing the Risk of Indwelling Catheter-Associated Urinary Tract Infection in Female Patients by Implementing an
Lorena Eckert1,2,3,4,5,6, Lisa Mattia1,2,3,4,5,6, Shilla Patel1,2,3,4,5,6
1Lorena Eckert, MSN, RN, WOC Nurse, Pressure Ulcer Prevention, Infection Prevention and Clinical Research, Tri-City Medical Center, Oceanside, California.
Purpose:
The purpose of this quality improvement project was to reduce catheter-associated urinary tract infection (CAUTI) risk for female patients by implementing a female external urinary collection (FEUC) device with suction as an alternative to indwelling catheter (IDC).
Participants And Setting:
Participants were female patients admitted to our 386-bed community hospital in Southern California and who required urinary management.
Approach:
We implemented a comprehensive CAUTI prevention program in 2014 that was in place for 1.5 years before this project was started. The CAUTI prevention program was based on the US Center for Disease Control and Prevention's CAUTI prevention recommendations. To supplement our CAUTI prevention efforts in our female patients, we implemented the FEUC device in our intensive care, telemetry, medical-surgical, orthopedic, and acute rehabilitations inpatient care units. Indwelling catheter use and CAUTI cases were identified by our Infection Prevention department.
Outcomes:
Prior to introduction of the FEUC device, in 2015, the baseline female IDC utilization rate was 31.7% (7181 IDC device-days/22,656 patient-days) and the female CAUTI rate was 1.11 (8 cases/7181 IDC device-days) per 1000 days. Following introduction of the device, both rates declined. In 2016, the IDC utilization rate was 29.7% (P = .000) and the CAUTI rate was 0% (P =.005). We continued to observe a reduction in 2017 IDC utilization rates of 26% (P = .000); the 2017 CAUTI rate of 0.90 was not significantly different to our prior year rate (P = .726).
Implications For Practice:
We found that the introduction of the FEUC device reduced the risk for CAUTI. We will continue to prioritize the use of external devices for urinary management to help reduce the risk of our patients developing CAUTI.
More Related Videos
Related Concept Videos
Urinary Tract Infection III: Diagnostic Studies and Interprofessional Care
Urinary Tract Infection IV: Nursing Management
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Urine Studies II: Urine Culture and Sensitivity Test
Endocarditis IV: Nursing Management
Urinary Tract Calculi V: Nursing Management